outlets. 5 mA of current is enough to cause the 
GFCI to trip; to troubleshoot this type of problem, 
start with nothing connected to the IT-Reference 
7’s  balanced  power  outlets.  Then,  add  each 
piece of equipment until the GFCI trips. Contact 
the manufacturer of the suspect unit for possible 
solutions.

I

n d I c at o r

  l e d

s

e

xtreme

 V

oltage

 s

hutdoWn

 I

ndIcator

This LED is normally off. It monitors AC wiring 
faults  –  for  example,  accidental  connection  to 
an open neutral from a 08 or 0VAC feed (this 
is a common occurrence if the AC outlet source 
is  not  a  dedicated  line,  but  instead  has  been 
wired with a daisy-chained neutral from a homes 
breaker box). The Series Multi-stage Protection 
(SMP) circuit senses voltages that are so high 
that  operation  would  be  impossible  and  shuts 
the  power  down  before  damage  can  occur. 
Upon  initially  applying  power  to  these  units, 
the  Extreme  Voltage  indicator  LED  will  light  if 
the input voltage is above the extreme voltage 
cutoff, and power will not be applied to the unit’s 
outlets.  If  the  unit  has  been  operating  with  an 
acceptable input voltage and subsequently that 
voltage exceeds 137V, it will shut off power to 
the  outlet  and  the  Extreme  Voltage  LED  will 
light.  

P

rotectIon

 ok I

ndIcator

 – F

ront

 P

anel

 b

lue

 

led P

oWer

 I

ndIcator

Although  the  Furman  SMP  circuit  assures 
virtually  maintenance  free  protection  from 
transient  voltage  spikes  and  surges,  nature 
has  a  way  of  occasionally  creating  electrical 
forces  that  are  beyond  the  capabilities  of  any 
Transient  Voltage  Surge  Suppression  device 
to  absorb  without  some  degree  of  damage.  In 
the rare instance that this occurs, the blue LED 
located in the center of the front panel will dim, 

even though AC power is present at the unit’s 
outputs. If this happens, some level of protection 
from  voltage  surges  will  remain,  but  the  unit’s 
clamping  voltage  rating  will  be  compromised. 
The  unit  must  be  returned  to  Furman  Sound, 
or  an  authorized  Furman’s  Service  center  for 
repair. 

d

ImmIng

 

the

 P

rotectIon

 ok F

ront

 P

anel

 

I

ndIcator

Some  installations  will  require  placement  of 
this power conditioner within sight of your video 
screen. When the rooms lights are fully dimmed 
for video viewing this can be an annoyance, so 
we have included a dim switch on the rear of the 
unit. This will not disable the indicator; it simply 
reduces its brightness.

NOTE:  If  the  mains  power  is  above  the  high  cutoff 
voltage  and  has  caused  the  unit  to  remove  power 
from  its  outlets,  it  cannot  restore  power  without  the 
operator manually turning the unit off, then on again. 

Avoid turning the unit back on without first checking 

the  source  of  the  problem  and  changing  the  AC 
source if necessary.

s

at e l l I t e

  –   c

a b l e

 

t

r a n s I e n t

  V

o lta g e

 

s

u r g e

  s

u P P r e s s o r s

 

The IT- Reference 7 features transient voltage 
surge  suppression  for  both  cable  and  satellite 
lines  utilizing  standard  coaxial  connectors.  As 
these  surge  suppressors  are  in-line,  they  will 
require  an  additional  cable  to  connect  from 
their  output  to  the  control  device  requiring 
protection.

All  in-line  surge  suppressors  feature  our 
exclusive ground-contamination-free technology. 
This aids in eliminating audio buzzing, and the 
video hum-bars that can result from typical in-

Summary of Contents for IT-Reference 7

Page 1: ......

Page 2: ...Discrete Symmetrical Balanced Power cancels hum inducing noise and video bars by breaking ground loops Linear Filtering Technology LiFT for unequaled audio and video clarity Series Multi Stage Protec...

Page 3: ...cal Power features total isolation from other components connected to other AC power sources This positively breaks noise inducing ground loops hum bars and power supply backwash between critical inte...

Page 4: ...r proper operation Any attempt to operate the IT Reference 7 without a safety ground is considered improper operation and will invalidate the warranty Power Source The power source to which the IT Ref...

Page 5: ...rmanently at a cost of pennies per month This is an added benefit as many audio videophiles find performance improves significantly when leaving low powered components permanently charged turned on In...

Page 6: ...Transient Voltage Surge Suppression device to absorb without some degree of damage In the rare instance that this occurs the blue LED located in the center of the front panel will dim even though AC...

Page 7: ...as to be covered by this warranty Furman shall authorize the purchaser to return the product to the Furman factory or to an authorized Furman repair location Warranty claims should be accompanied by...

Page 8: ...ery charger To be used indoors only and in dry areas All warranties contained herein are null and void if used in anyway with any of the aforementioned devices THE FOREGOING IS IN LIEU OF ALL OTHER WA...

Page 9: ...Registration Card was mailed in at the time of purchase or if the product was registered on line this is not necessary Before returning any equipment for repair please be sure it is adequately packed...

Page 10: ...00 ohms line impedance Common Mode 85 dB 10Hz to 20 kHz 40 dB 20kHz to 1MHz Outlets 4 symmetrical balanced outlets Transient Voltage Surge Suppression 120VAC Line Series Multi stage Non Sacrificial wi...

Page 11: ...IT Reference 7 Owner s Manual 11...

Page 12: ...Furman Sound Inc 1997 South McDowell Blvd Petaluma California 94954 6919 USA Phone 707 763 1010 Fax 707 763 1310 Web www furmansound com E mail info furmansound com 0512 01 A...

Reviews: