Connection Status Lights

Each multi-color Connection Status Light provides information on the 
Miniports’ communication links.  There are two LEDs, labeled PRIMARY 
LINK and SECONDARY LINK that are associated with the SmartSequencer 
link communications system.  Each of these LEDs can illuminate Red, 
Green, or amber. When a number of Miniports are connected together 
via their SmartSequencer link ports, the LEDs will illuminate Green and 
occasionally blink as messages are passed between units.

SmartSequencing Note: When there are two or more SmartSequencer 
units linked in series, a slowly blinking Green Primary Link LED identi-
fies the Primary Unit.  Similarly, a SmartSequencer displaying a solid 
Green Primary Link LED would indicate the unit is the last Secondary in 
the chain of sequencers. Secondary Units in the middle of the chain will 
display both a solid Green Primary Link LED and a solid Green Second-
ary Link LED. The Connection Status Link Indicators will flash accordingly 
during power up and power down as SmartSequencer messages are sent 
between units.

Green LED status is a sign of good communications. If a Contractor Series 
unit is used independently (no connections) and the unit is configured as 
a Primary Unit (DIP 8, ON or UP), the Primary Link LED will slowly blink 
Green at 1 second intervals.  If there is a SmartSequencer link connecting 
a Primary Unit to a Secondary Unit, the Primary unit will send messages 
to the Secondary Unit and the Secondary Link LED will illuminate Green 
on the Primary Unit, indicating there is an established communication 
link with a the Secondary Unit. On Secondary units (DIP Switch 8, OFF or 
DOWN), the Primary Link LED will be Green, indicating there is communi-
cation to a Primary.

The Red Connection status LED can sometimes illuminate briefly if a 
message is lost corrupted on the SmartSequencing link.  Unless the Red 
LED is illuminated continuously, this should be no cause for concern.  The 
SmartSequencing protocol is robust and redundant.  As long as a physical 
link is in place, the message will eventually get through.

A continuous Red Connection Status LED indicates that a unit has no 
SmartSequencing link connection where the unit has been configured to 
expect link communications.  This occurs when a Secondary Unit cannot 
communicate with surrounding units in a SmartSequencing chain. The 
result is that the Secondary Units Primary Link LED may be Red because 
the link is broken to a Primary Unit or the Secondary Link LED may be 
Red because the link is broken to a Secondary Unit.  This could also 
mean that the Secondary Unit sees the Primary Unit, but the Primary Unit 
does not see its Secondary.

The Amber LED may be seen upon start up initialization or as communi-
cation ensues between Smart Sequencers. This Amber LED state should 
resolve to a Red or Green state. If the amber indication does not resolve, 
please contact Furman Support.

Power Indicator

One POWER LED is provided to indicate the ON or OFF state of the power 
outlet. If power is provided to the outlet, the LED will illuminate green.  If 
the Miniport is operating under safe power conditions and no utility fault 
conditions exist the POWER LED will remain steadily lit. Once triggered to 
power-down the POWER LED will go off as the power outlet is deacti-
vated. 

EVS LED

The EXTREME VOLTAGE LED indicator is normally OFF. The EVS function 
is tied to this LED and monitors the incoming voltage for out of tolerance 
conditions. If enabled, the EVS will disable the AC power before damage 
can occur.  The EXTREME VOLTAGE LED will be illuminated Red anytime 
the voltage is found to be below 77 volts or more than 145 volts.  The 
EVS LED will remain illuminated, and the outlets will be disabled as long 
as an out of tolerance condition exists.

CN-15MP

If the combined current, drawn by all devices plugged into the CN-15MP 
exceeds 15 Amps at any time, the circuit breaker will “trip’, cutting off 
power to all connected devices.  If this occurs; the operator must reduce 
the load by unplugging one or more devices from the CN-15MP, and reset 
it. The operator can reset the circuit breaker by pressing in the circuit 
breaker button. However, because the safety feature is a thermal breaker, 
it is suggested that you wait one minute after the “trip” occurs to allow 
the breaker to cool down before resetting.

CN-20MP

The CN-20MP does not have an integral circuit breaker and relies on 
the branch circuit breaker to limit the current to the loads. The CN-20MP 
must be connected to a branch circuit equipped with a 20 Amp breaker, 
and capable of sustained 20 Amp service.  If the branch circuit breaker 
trips, the operator must reduce the load by unplugging one or more 
devices from the CN-20MP.

CLASS 2 WIRING 

CN-15MP

  FORCE 

OFF

P

P

S

S

   

 

 

 

PRIMARY

LINK

SECONDARY

LINK

POWER

SMARTSEQUENCING                               

OUT

IN

120 VAC, 50/60 Hz

MAX LOAD 15A

15 AMP

MINIPORT

+12V

STAT

REM

GND

DLY OUT

 REMOTE 

PORT

EXTREME VOLTAGE

C                  US

Circuit Breaker

The CN-15MP is equipped with a 15 Amp thermal circuit breaker button 
which will pop outward if the amount of current distributed to all loads 
exceeds 15 Amperes.  The CN-20MP does not have a circuit breaker.

C                  US

15 AMP

MINIPORT

120 VAC, 50/60 Hz

MAX LOAD 15A

POWER

EXTREME VOLTAGE

CLA

SS 2

 WIR

ING

 

  FORCE 

OFF

P

P

S

S

SECONDARY

LINK

SMAR

TSEQUENCING

                               

OUT

IN

+12V

STAT

REM

GND

DLY OUT

 REMO

TE 

POR

T

PRIMARYLINK

BYPASS

120 

VAC 

   /60/HZ
    A MAX.

15 AMPS

PUSH TO RESET

C                  US

CN-15MP

120 

VAC 

   /60/HZ
    A MAX.

120 

VAC 

   /60/HZ
    A MAX.

C                  US

20 AMP

MINIPORT

120 VAC, 50/60 Hz

MAX LOAD 20A

POWER

EXTREME VOLTAGE

CLA

SS 2

 WIR

ING 

  FORCE 

OFF

P

P

S

S

SECONDARY

LINK

SMAR

TSEQUENCI

NG                            

   

OUT

IN

+12V

STAT

REM

GND

DLY OUT

 REMO

TE 

POR

T

PRIMARYLINK

BYPASS

C              

    US

CN-20MP

CN-

15MP Circuit Breaker

CN-20MP No Circuit Breaker

CLASS 2 WIRING 

CN-15MP

  FORCE 

OFF

P

P

S

S

   

 

 

 

PRIMARY

LINK

SECONDARY

LINK

POWER

SMARTSEQUENCING                               

OUT

IN

120 VAC, 50/60 Hz

MAX LOAD 15A

15 AMP

MINIPORT

+12V

STAT

REM

GND

DLY OUT

 REMOTE 

PORT

EXTREME VOLTAGE

C                  US

CLASS 2 WIRING 

CN-15MP

  FORCE 

OFF

P

P

S

S

   

 

 

 

PRIMARY

LINK

SECONDARY

LINK

POWER

SMARTSEQUENCING                               

OUT

IN

120 VAC, 50/60 Hz

MAX LOAD 15A

15 AMP

MINIPORT

+12V

STAT

REM

GND

DLY OUT

 REMOTE 

PORT

EXTREME VOLTAGE

C                  US

Summary of Contents for CONTRACTOR MINIPORT CN-15MP

Page 1: ...P A S S C U S CN 20MP CN 15MP Contractor Grade Power Management with SmartSequencing Technology Features SmartSequencing technology allows large complex A V systems to be safely power cycled on and o...

Page 2: ...g power to the amplifiers When shutting down the A V system a sequencer will turn off the system in the reverse order hence the amps will be turned off first and then the signal processing equipment w...

Page 3: ...urrent loop In situations where power sequencing is critical or more than one AC electrical circuit is utilized wiring Furman SmartSequencing products in series is simple fast and reliable EVS EXTREME...

Page 4: ...the manufacturer 10 Refer all servicing to qualified personnel Servicing is required when the unit has been damaged in any way or fails to operate 11 WARNING Do not use power cord as the main power d...

Page 5: ...ON 12V OFF GND ON MOM MNT PRI SEC EVS AUTO MANUAL 6 7 8 9 1 2 3 4 5 6 7 8 9 ON FOR REFERENCE ONLY ABBREVIATED DESCRIPTIONS AS SHOWN ON THE PRODUCT NOT FOR SETTING S INSTRUCTIONS EXAMPLE 1 DIAGRAM SMA...

Page 6: ...A EXAMPLE 3 DIAGRAM LARGE LEGACY UPGRADE EXAMPLE 4 DIAGRAM LARGE SET UP PRIMARY CONTROLLED VIA RS 232 P P S S CN 1800S 12 STAT REM GND UNIT 3 SECONDARY INTERFACE NO NC C FORCE OFF FORCE OFF P P S S CN...

Page 7: ...o the Secondary IN of the next downstream sequencer A Furman SmartSequencing chain communicates using a bucket brigade technique A Primary Unit communicates to the first Secondary Unit downstream by s...

Page 8: ...control system is either inaccessible or commanding the outputs to an OFF state It should be noted that the FORCE OFF and EVS conditions have priority over the BYPASS switch and if either of these co...

Page 9: ...will be triggered when the short between the two FORCE OFF pins is removed If a FORCE OFF is triggered the FORCE OFF message will be propagated to all SmartLink connected devices The power to all of t...

Page 10: ...ate as a Secondary Sequencer 8 1M 1 2 3 4 5 2M 4M N O N C 12V ON 12V OFF GND ON MOM MNT PRI SEC EVS AUTO MANUAL 6 7 8 9 1 2 3 4 5 6 7 8 9 9 1M 1 2 3 4 5 2M 4M N O N C 12V ON 12V OFF GND ON MOM MNT PRI...

Page 11: ...utlet If power is provided to the outlet the LED will illuminate green If the Miniport is operating under safe power conditions and no utility fault conditions exist the POWER LED will remain steadily...

Page 12: ...ect the signal processing equipment to the Mini ports near the beginning of the chain and the Amplifiers to the sequenc ers nearest the end of the chain This will ensure that the power to the signal p...

Page 13: ...lative Humidity User Interface Thermal Circuit Breaker Bottom panel pushbutton CN 15MP only Front panel diagnostic indicators Primary link Secondary link Power Extreme Voltage Side Panel DIP Switches...

Reviews: