![Funkwerk 800ATC-(200)-(200) Operation And Installation Download Page 11](http://html1.mh-extra.com/html/funkwerk/800atc-200-200/800atc-200-200_operation-and-installation_2346520011.webp)
TRT800 / P/N 800ATC-(200)-(200)
Operation and Installation
11
Document-No: 03.2102.010.71e / Revision: 2.02
Value
Meaning
Remarks
diamond
Transponder is transmitting:
Replies on Interrogations
Extended Squitter
(ADS-B out)
•
Appears per reply
7000 active
Squawk
I
Transponder is locked by a
ground station and will be
directly addressed
Lock Information (indicated
as vertical dash below the
diamond)
PLL
PLL Error
Internal Error
TRX
DC
Transmit Failure
Low current
Internal error
FPG FPGA-Failure
Internal
error
BAT
Battery Power too low
maybe battery/generator fault
IDT
transmits Ident-Marking (SPI) ID („Squawk Ident“) has been
pressed – active for 18 s
FL010
FLerr
Flight Level
Invalid altitude measuring
Flight Level (in 100 ft steps)
Beyond -1000 .. 35 000 ft,
C Mode gets active
ACS Opertional
Mode
(STBY, A-S, ACS, AC, A)
Modes see section 2.5
0000
Standby Squawk
Could be changed with active
Squawk by pressing
F
G
in-flight
on-ground
Ground-Switch-Info
(if installed/available)
Cradle
Off
no AA (24bit-Address)
configured
Transponder works in A/C-
Mode (no Mode-S)