ft636 (14.10.2013)
- 24 -
Kompetent für Elektroniksysteme
ft636 (14.10.2013)
- 25 -
Kompetent für Elektroniksysteme
Configuration AF-Delay Voip > Line
For the delay the remaining available RAM is used. This delay can be shorter for later versions or
special software versions. The specified maximum delay time may then be shorter.
This delay time is shared by both radio circuits. At first the programmed value for radio circuit 1 is
set. Only the remaining RAM is then available for radio circuit 2, so that maybe the programmed
time cannot be set.
1.-4. digit: nnn * 1ms NF Delay Voip > Line
5. digit: compression:
0 = none (max. 125ms)
1 = A-law (max. 250ms)
2 = half baud rate (max. 250ms)
3 = A-law and half baud rate (max. 500ms)
Vox configuration
1.-2. digit: nn*5ms above threshold value, until PTT on
3.-4. digit: ca. nn*1,8mV threshold value PTT on
5.-6. digit: n*5ms below threshold value, until PTT off
7.-8. digit: ca. nn*1,8mV threshold value PTT off
PTT-configuration
1. digit: PTT signaling to line
0 = programmed pilot tone
2.-5. digit: pilot tone- or TRC-Guardtone frequency
1000s, 100s, 10s,1s Hz
6. digit: Vox for Voip use for PTT
yes = 1
no = 0
Decoder reference 1
1.-3. digit nnn*5ms tone duration 1. tone
4.-5. digit tone duration all tones
Decoder reference 2
1.-3. digit nnn*5ms tone duration from 2nd tone on
5. digit call tone system line 0
0 = ZVEI
1 = CCIR
2 = ZVEI2
3 = EEA
4 = ZVEI3
Encoder reference
1.-2. digit nn*10ms tone duration 1. tone
3. digit n*10ms all other tones
4.-5. digit nn*10ms pause time between call id and own id tone sequence
Group-call decoder reference
1.-2. digit nnn*100ms min. tone duration single tone decoder
3.-4. digit nnn*100ms max. tone duration single tone decoder
(00, as soon as min. duration is reached)
5.-6. digit nn*100ms min. tone duration special tone decoder (tone call 1/2)
7.-8. digit nn*100ms max. tone duration special tone decoder (tone call 1/2)
(00, as soon as min. duration is reached)
Summary of Contents for FT 636
Page 1: ...IP Interface FT 636...