Gateway IP address
Enter the 4 values for the gateway IP address, for example:
„0.0.0.0“ for no gateway
„192.168.0.1“ for one gateway in the LAN
Please note: The gateway only has to be entered, if the connection is made via WAN (by a rou-
ter/ a gateway).
Default: „0.0.0.0“
Primary DNS server
Here you can enter DNS Servers for name resolution (for example www.funktronic.de).
Example: „195.186.1.111“
Default: „0.0.0.0“
Alternative DNS
A further DNS server, if the first cannot be contacted.
Example: „195.186.4.111“
Default: „0.0.0.0“
Port for audio / AF
Port by which the audio/AF data are transmitted.
Port for signaling
Port by which the signaling (PTT, squelch, channel switching, etc..) is transmitted.
Web server port
Port by which the integrated webserver is contacted. If set on „0“, the standard HTTP port (80)
will be used.
SERIAL INTERFACE 1
Settings for the serial interface.
Baud rate
Transmission rate („300“ to „230400“ Baud).
Default: „9600“
Data bits
Select „7“ or „8“ data bits.
Default: „8“
Parity
Selection between „no“, „even“ or „uneven“ parity.
Default: „no“
Stop bits
Select „1“ or „2“ stop bits.
Default: „1“
Handshake
Select the kind of handshake:
RTS/CTS not used: „no“
RS232/RS422: „Software flow control XON/XOFF)“
Default: „no“