User information EN
Technical data
25
DECT™ Base-Stations FB4 IP (TP ⁄ FX) | User Information
Last Update: 29.08.2016
Connector pin assignments
Connector pin assignments of Western sockets
Western socket
Connector pin assignment
Remark
8-pin RJ-45
Phantoms power supply
Active PoE:
– Pin1,2 --> RX and DC+
– Pin3,6 --> RX and DC—
Passive PoE power supply:
– Pin4,5 --> DC+
– Pin7,8 --> DC—
(Fast) Ethernet,
Assignment according to
IEEE802.3u 100BASE-TX or
IEEE802.3u 10BASE-TX
LC socket (Lucent
connector)
Connection for a fibre-optic
multimode fibre data connec-
tion:
– The fibre-optic signals TX
and RX are marked by
arrows on the upper cover.
• TX marking =
• RX marking =
Assignment according to
IEEE802.3u 100BASE-FX
• The LC plug is also marked
with RX and TX arrows. The
arrows on the upper cover and
on the properly plugged-in LC
plug must match and point to
the same direction.
• Please bear in mind: An open
unused LC socket must be kept
closed with the original rubber
plug as a protection against
dirt!
6-pin RJ-12
Power supply connection:
– Pin1 --> 48V DC—
– Pin6 --> 48V DC+
– max. 80mA
System-compatible plug-ion
power supply unit or
customer-provided power
supply
4-pin RJ-10 (2
contacts are used)
Connection for the input
contact:
– Pin1
– Pin2
The maximum allowed line
connection resistance
between the external switch
and the contact input is 100
Ohm.
Summary of Contents for FB 4 IP
Page 1: ...DECT Basisstation FB 4 IP Benutzerinformation DECT Base Station FB 4 IP User Information...
Page 4: ...Inhalt Table of Contents 4...
Page 29: ...29 DECT Basis FB4 IP Benutzerinformation Letzte Aktualisierung 29 08 2016...
Page 30: ...30...
Page 31: ...31 DECT Basis FB4 IP Benutzerinformation Letzte Aktualisierung 29 08 2016...