background image

Abb. / Fig. 4

verrastend / locking 

nicht verrastend /

non-locking

Verrastungsschema / Locking diagram 

6

Abb. / Fig. 2

Anschluss-
klemmen /
Connecting
terminals

Anschluss-
raum / 
Terminal
room

Modul / Module

Schalter /
Switch

Anschlussplan / Wiring diagram

Abb. / Fig. 3

Brand-
melde-
leitung / 
Fire alarm
cable 

Verschraubung /
Cable gland 

Druckschraube /
Pressure screw 

Kabeleinführung / Cable gland

Summary of Contents for 2014/2

Page 1: ...onstruktion zertifiziert nach Verordnung EU Nr 305 2011 für Bauprodukte FHF BA 2013 1 01 16 1 Abb Fig 1 Abmessungen Dimensions 88 136 155 75 138 Befestigungsmaße Fastening measurements Areas of Zones 1 and 2 21 and 22 Class II and III IP 66 IEC 60529 degree of protection Temperature range 55ºC to 70ºC or 65ºC Plastic housing Fibre reinforced polyester All metal parts consist of stainless steel V4A...

Page 2: ...bisolieren und durch Druckschrau be und Kabelverschraubung führen Einzeladern an den Enden ca 5 6 mm abisolieren damit ein sicherer Kontakt gewährleistet ist Die Verdrahtung im Inneren des Anschlussraumes darf nicht an das Verriegelungsystem des Knopfes gelangen damit eine Verrastung sichergestellt ist Die Aderisolation der Leiter muss soweit an der Anschlussklemme liegen dass zwischen den leitfäh...

Page 3: ...je nach gewünschter Funktion rechts oder links vom Verriege lungstab in die Befestigungs bohrung geschraubt Soll ein Umbau in eine der beiden Varianten gewünscht werden so wird die Befestigungsschraube der Feder gelöst die Feder zur ent sprechenden Seite gelegt und mittels Schraube wieder befestigt Anschließend Deckel montieren und Tür wie beschrieben schließen Wartung und Pflege Der Feuermelder i...

Page 4: ... the ter minal room and guide it through the pressure screw and the cable gland Remove approx 5 6 mm of the isolation from the end of the conductors in order to establish good electrical contact The wiring on the inside of the terminal room must not reach the locking system of the button in order to ensure the locking system works properly The conductor isolation of the cable must extend so far to...

Page 5: ... valid for the special alarm too Recycling The device may be completely recycled as electronic waste When the device is disassembled plastics metals and electronics are to be disposed of separately In every single case the national requirements and regulations for waste disposal must be observed Technical Specifications Type 2014 2 and 2014 2 GLU Device name Fire alarm Type B according to EN 54 11...

Page 6: ...king diagram 6 Abb Fig 2 Anschluss klemmen Connecting terminals Anschluss raum Terminal room Modul Module Schalter Switch Anschlussplan Wiring diagram Abb Fig 3 Brand melde leitung Fire alarm cable Verschraubung Cable gland Druckschraube Pressure screw Kabeleinführung Cable gland ...

Page 7: ...7 ...

Page 8: ...8 ...

Page 9: ...9 ...

Page 10: ...ner Instandsetzung oder einem Austausch des Gerätes muss es von der Spannungs versorgung getrennt werden Wenn eine Wartung oder eine Reparatur unter Spannung un vermeidbar ist darf das nur von einem unterwiesenen Fachmann geschehen 8 Die vorgeschriebene Gebrauchslage ist zu berücksichtigen 9 Das Wechseln oder Ergänzen von Modulen darf nur von einem Fachmann durchgeführt werden Es sind nur Module z...

Page 11: ... may cause damage 7 Before the device is repaired or replaced it must be disconnected from the power supply If the maintenance or repair of a live device cannot be avoided this must be done by authorised personnel only 8 Take into consideration the required operating position 9 Replacing or amending modules must be carried out by a trained technician only Use only modules that are certified for in...

Page 12: ... 45478 Mülheim an der Ruhr Web www fhf de Phone 49 208 8268 0 Fax 49 208 8268 286 Mail info fhf de Orders fhf orders eaton com Requests fhf sales eaton com Support fhf support eaton com Änderungen und Irrtum vorbehalten Subject to alterations or errors ...

Reviews: