2-2-7
L0605DCP
5-3. How to Adjust
(1) Adjusting initial voltage wave form
Check the voltage wave form like the mentioned way on the 4-3(How to adjust) and readjust the wave form
when it is wrong.
(2) Checking the DC/DC pack voltage
a. Convert the signal of signal generator to the 100% Full White signal
b. Connect the GND terminal of DVM to the R30’s right leg of the Y B/D and set the Plus terminal to the left
leg of R30 to check the Vscw voltage(115
±
1V) and when there is abnormality in voltage turn the variable
resistor(VR5) of DC/DC Pack (Vscw) on Y B/D to adjust.
c.
Connect the GND terminal of DVM to the R31’s right leg of the Y B/D and set the Plus terminal to the left
leg of R31 to check the -Vy voltage (-75
±
1V) and when there is abnormality in voltage turn the variable
resistor (VR6) of DC/DC Pack (-Vy) on Y B/D to adjust.
d. Connect the GND terminal of DVM to the R27’s right leg of the Y B/D and set the Plus terminal to the left
leg of R27 to check the Vsetup voltage (200
±
1V) and when there is abnormality in voltage turn the vari-
able resistor(VR4) of DC/DC Pack (Vsetup) on Y B/D to adjust.
(3) Measuring the Vs voltage Margin and deciding the voltage
a. Convert the signal of signal generator to the 100% Full Red signal.
b. Turn the voltage adjusting knob of Vs DC power supply to the voltage -down direction and make the cell of
screen turned off.
c.
Turn the voltage adjusting knob of Vs DC power supply to the voltage -up direction until the cell of screen
turned on. The first voltage, which make the cell of full screen turned on, is named as Vsmin1 and record
it.
d. Turn the voltage adjusting knob of Vs DC power supply to the voltage-up direction slowly until the cell of
screen turned off or over electric discharge. The first voltage, which makes the cell of screen turned off or
over electric discharge, is named as Vsmax1 and records it (Only, Vs voltage variable passes over the
maximum 190V)
e. Convert the signal of signal generator to the 100% Full Green signal.
f.
Repeat the adjustment (2) item and name each voltage as Vsmin2/Vsmax2 and record them.
g. Convert the signal of signal generator to 100% Full Blue signal.
h. Repeat the adjustment (2) item and name each voltage as Vsmin3/Vsmax3 and record them.
i.
Convert the signal of signal generator to 100% Full White signal.
j.
Repeat the adjustment (2) item and name each voltage as Vsmin4/Vsmax4 and record them.
k.
Convert the signal of signal generator to 100% Full Black signal.
l.
Repeat the adjustment (2) item and name each voltage as Vsmin5/Vsmax5 and record them.
m. At this time decided Vs voltage adds 6V to Max value(Vsmin1~Vsmin5) and set up the voltage within the
set-up range(180V
<
Vs
≤
190V) in consideration of other features.
n. Turn the voltage adjusting knob of Vs DC power supply make deciding the Vs voltage.
o. Adjust Vset-down wave form using setting up Vs voltage like mentioned on the 4-3.
(4) Adjusting the final voltage wave form
Check the voltage wave form like the mentioned way on the 4-3(How to adjust) and readjust the wave form when
it is twisted.
(5) DC-DC Pack Voltage Set up Range
Vsetup: 185V ~ 225V
Vsc: 90V ~ 120V
-Vy: -60V ~ -80V
Summary of Contents for F42PDME
Page 5: ...1 1 2 L0605SP DIMENSIONS 1314 920 1 600 907 47 393 77 120 518 4 83 6 97 692 ...
Page 23: ...1 5 8 L0605DC 25 Stand Unit S 26 S 26 Fig 8 ...
Page 27: ...1 5 12 L0605DC Clamper Clamper Fig 13 Cables on the Filter CBA Filter CBA Earth Clamper CN801 ...
Page 52: ...1 9 21 Analog CBA Bottom View 1 9 22 BL0600F01013 1 ...
Page 53: ...Switch CBA Top View Switch CBA Bottom View 1 9 23 1 9 24 BL0600G04013 2 ...
Page 56: ...TP2037 WF4 TP2038 WF5 Digital CBA Bottom View 1 9 29 1 9 30 BL0600G04013 1 ...
Page 88: ...2 5 1 L0605PCEX 1 8 4 3 2 7 6 5 EXPLODED VIEWS OF PDP MODULE ...
Page 90: ...F42PDME L0605UF 2004 12 13 ...