1-6-1
L0605EA
ELECTRICAL ADJUSTMENT INSTRUCTIONS
General Note:
"CBA" is abbreviation for "Circuit Board Assem-
bly."
NOTE:
Electrical adjustments are required after replacing
circuit components and certain mechanical parts.
It is important to perform these adjustments only
after all repairs and replacements have been com-
pleted.
Also, do not attempt these adjustments unless the
proper equipment is available.
Test Equipment Required
1. NTSC Pattern Generator (Color Bar W/White Win-
dow, Red Color, Gray Scale)
2. Plastic Tip Driver
3. Remote control unit: Part No. N0105UD, N0108UD,
N0127UD or N0132UD
4. Color Analyzer
How to make service remote control
unit:
1. Prepare normal remote control unit. (Part No.
N0105UD, N0108UD, N0127UD or N0132UD) Re-
move 3 Screws from the back lid. (Fig. 1-1)
2. Add J1 (Jumper Wire) to the remote control CBA.
(Fig. 1-2)
How to set up the service mode:
Service mode:
1. To turn the power on, press "POWER" button on the
normal remote control unit or the unit.
2. Use the service remote control unit.
3. Press "SLEEP" button on the service remote con-
trol unit. Fig. 2 appears on the screen.
4. Confirm the following
a. Version of main micro
computer --- PZ1_US_LF_Ver1.29 (or 1.31)
b. Version of sub micro computer --- K746_015
c. Memory size --- 32
d. FLASH DATA Check-Sum (press "0" button on
the service remote control unit) --- D2F7h (or
E170h)
Initial setting:
1. To turn the power on, press "POWER" button on the
normal remote control unit or the unit.
2. Enter the service mode.
3. To reset to factory setting, press "DISPLAY" but-
ton on the service remote control unit.
- "INITIALIZE" (red) appears on the screen as
shown in Fig. 3.
- After few seconds (completion initialization), col-
or of "INITIALIZE" will change green.
SCREW
REMOTE CONTROL UNIT
Fig. 1-1
J 1
Fig. 1-2
REMOTE CONTROL CBA
MAIN UCOM Ver.
SUB UCOM Ver.
MEMORY SIZE
CHKSUM
: PZ1_US_LF_Ver1.29 (or 1.31)
: K746_015
: 32
: Push 0 key
Fig. 2
MAIN UCOM Ver.
SUB UCOM Ver.
MEMORY SIZE
CHKSUM
: ********
: ********
: 32
: ****
INITIALIZE
Fig. 3
Summary of Contents for F42PDME
Page 5: ...1 1 2 L0605SP DIMENSIONS 1314 920 1 600 907 47 393 77 120 518 4 83 6 97 692 ...
Page 23: ...1 5 8 L0605DC 25 Stand Unit S 26 S 26 Fig 8 ...
Page 27: ...1 5 12 L0605DC Clamper Clamper Fig 13 Cables on the Filter CBA Filter CBA Earth Clamper CN801 ...
Page 52: ...1 9 21 Analog CBA Bottom View 1 9 22 BL0600F01013 1 ...
Page 53: ...Switch CBA Top View Switch CBA Bottom View 1 9 23 1 9 24 BL0600G04013 2 ...
Page 56: ...TP2037 WF4 TP2038 WF5 Digital CBA Bottom View 1 9 29 1 9 30 BL0600G04013 1 ...
Page 88: ...2 5 1 L0605PCEX 1 8 4 3 2 7 6 5 EXPLODED VIEWS OF PDP MODULE ...
Page 90: ...F42PDME L0605UF 2004 12 13 ...