3.3 Area of use
Since the product does not have an internal
ignition source, it cannot be classified under
the ATEX directive 2014/34/EU.
The ME EX extraction arm is designed for the safe
extraction of gas and dust in explosive atmospheres.
The product complies with the requirements of the ATEX
directive for category 2 equipment for gas and dust, and
it is suitable for use in zones 1 and 21 as well as 2 and 22.
3.4 Design
See
1.
Hood*
2.
Joint
3.
Damper
4.
Tube B
5.
Tension knob
6.
Tube A
7.
Gas spring**
3.5 Function
The ME EX extraction arm is an extractor arm for
capturing and extracting gases and dust-filled air in
explosive atmospheres.
The extraction arm’s swivel (8) rotates a full 360° and
can be mounted on a table, wall- or ceiling bracket (9).
The arm is fitted with a torsion spring (inside the joint)
or gas springs (7) to counterbalance the weight of the
arm. The joint friction (2) can be altered with the tension
knob (5) found on each joint. An adjustable damper (3)
is used to completely block or adjust the airflow. Each
bracket comes with an earth cable (10) to be connected
to the earth at the facility.
For hoods and brackets, see Chapter
.
8.
Swivel
9.
Bracket*
10.
Earth cable
11.
Earthing screw
12.
Connection tube
13.
Earthing plate***
14.
Earth measuring point***
Fig. 2
* Accessories
** On certain models
*** MEB only