Part # FA201D – Gas/Odor Filter 

Most process plumes contain several gases, some odorous – some not, some toxic at elevated concentrations – 
some completely harmless regardless of concentration.  To ensure employee safety the type and concentration 
of pollutants must be determined.  Please contact Fumex Engineering for filter selection assistance.  These filters 
utilize a blended activated carbon and activated alumina impregnated with KMnO4 filter to capture and treat 
gases/odors.  This combination of materials provides protection across a broad range of gases commonly found 
in industrial manufacturing processes. 

 

G E N E R A L   M A I N T E N A N C E  

 

1)  The blower motor is a sealed unit, 24,000 hr. MTBF rated.  It is permanently lubricated and does not require 

oiling – keep it free of dust accumulations to prevent overheating. 

2)  Remove any loose accumulations of dust/debris from the air filter chamber periodically. 
 

“This product employs overload protection (fuse). A blown fuse indicates an overload or short-circuit situation. If 
the fuse blows, unplug the product from the outlet. Replace the fuse as per the user servicing instructions (only 
10-Amp fuse) and check the product. If the replacement fuse blows, a short circuit may be present and the 
product should be discarded or returned to an authorized service facility for examination and/or repair”. 

 

Remote Interface and Connectivity Function 

The GS1-100 unit can be supplied with an optional interface package providing remote start/stop and filter 
monitoring capabilities (Part # FA228).  Please see instructions below for Relay Activation/De-Activation 
procedures and refer to the drawing in Figure 1 for remote connections.   
 
 
 
 
 
 

WARNING 

“To Prevent the Risk of Electrical Shock, Connect Remote Interface 

Cable to 24v, Class 2 Power Supply Only” 

 

 

 

 

 

WARNING 

“Disconnect From All Power Supplies Before Servicing” 

 

 

 

 

 

 

 

 

Summary of Contents for GS1-100

Page 1: ...any solid state speed control device WARNING For general ventilating use only Do not use to exhaust hazardous or explosive materials or vapors WARNING Use only a 10 Amp fuse CAUTION Do not operate wit...

Page 2: ...i n g t h e a i r c l e a n e r Placing the GS1 100 unit as close as possible to the pollution source reduces the amount of ducting needed reduces back pressure lowers power consumption and improves o...

Page 3: ...Filter and then press the FILTER RESET button If the light remains illuminated or turns off and comes back on then contact Fumex for assistance The GS1 100 unit contains a VOC sensor to detect odors g...

Page 4: ...2 Remove any loose accumulations of dust debris from the air filter chamber periodically This product employs overload protection fuse A blown fuse indicates an overload or short circuit situation If...

Page 5: ...nnesaw GA 30152 There are no warranties which extend beyond the descriptions set forth in this warranty notwithstanding any knowledge of Fumex LLC regarding the use or uses intended to be made of good...

Page 6: ...flash drive with a configuration file and the USB port on the control board Contact Fumex to acquire the correct configuration file for your unit 8 Reprogram the software by changing the remoteSwitchO...

Page 7: ...ia a flash drive with a configuration file and the USB port on the control board Contact Fumex to acquire the correct configuration file for your unit 8 Reprogram the software by changing the remoteSw...

Page 8: ...8 DRAWINGS AND FIGURES Figure 1...

Page 9: ...9 DRAWINGS AND FIGURES Figure 2 Figure 3 ON OFF Relay Activation Switch...

Reviews: