background image

 

CONTROLS

 

 

On/Off Switch 

 

Simple one touch controls – The green light above the POWER button will illuminate confirming power to the 
unit.       
 

Blower/Fan 

 

The GS1-100 unit utilizes a variable speed blower with three speed settings.  Press the up and down arrow 
buttons to increase/decrease blower speed.  A green light next to the specific speed (Low, Med, or High) will 
indicate speed setting.  In the case of a blower failure, all 3 blower speed lights will flash.  To reset the blower’s 
internal thermal protection, disconnect the unit momentarily from its power source and reconnect.  If the lights 
continue to flash contact Fumex LLC. for replacement information. 
 

Filter monitoring 

 

The GS1-100 unit utilizes a pressure differential switch to monitor the status of the Pre-filter.  The system 
monitors across all filters simultaneously and the Red “FILTER” light will illuminate when the Pre-filter needs to 
be replaced. The recommended procedure is to replace the Pre-Filter and then press the “FILTER RESET” button.  
If the light remains illuminated or turns off and comes back on then contact Fumex for assistance. 
 
The GS1-100 unit contains a VOC sensor to detect odors/gases in the exhaust stream. When the gas/odor filter 
becomes saturated and breakthrough of the VOC occurs the “GAS” warning light will illuminate.  

 

GENERAL FILTER CARE   

 

Fumex’s GS1-100 air purifier features a multi-stage filtration system designed to remove a wide range of 
pollutants from the process plume in an extremely efficient, cost-effective manner. The sytem utilizes a pressure 
differential switch to indicate blocked / clogged filters.  Once the warning lights illuminate, filters should be 
checked and clogged filters replaced.   
 

S T A N D A R D   F I L T E R S :  

 
Part # FA103 – Polyester pre-filter

 

The disposable polyester pre-filter is the first stage of the filtration process.  Its main function is to remove dust 
particles 100

µ

 and larger in advance of the more expensive pleated panel filter. 

 

Replacement: 

The service life of the polyester pre-filter is determined by the type and volume of large particles collected.  
Average service life is 4-6 weeks     

 

 

 

 

Summary of Contents for GS1-100

Page 1: ...any solid state speed control device WARNING For general ventilating use only Do not use to exhaust hazardous or explosive materials or vapors WARNING Use only a 10 Amp fuse CAUTION Do not operate wit...

Page 2: ...i n g t h e a i r c l e a n e r Placing the GS1 100 unit as close as possible to the pollution source reduces the amount of ducting needed reduces back pressure lowers power consumption and improves o...

Page 3: ...Filter and then press the FILTER RESET button If the light remains illuminated or turns off and comes back on then contact Fumex for assistance The GS1 100 unit contains a VOC sensor to detect odors g...

Page 4: ...2 Remove any loose accumulations of dust debris from the air filter chamber periodically This product employs overload protection fuse A blown fuse indicates an overload or short circuit situation If...

Page 5: ...nnesaw GA 30152 There are no warranties which extend beyond the descriptions set forth in this warranty notwithstanding any knowledge of Fumex LLC regarding the use or uses intended to be made of good...

Page 6: ...flash drive with a configuration file and the USB port on the control board Contact Fumex to acquire the correct configuration file for your unit 8 Reprogram the software by changing the remoteSwitchO...

Page 7: ...ia a flash drive with a configuration file and the USB port on the control board Contact Fumex to acquire the correct configuration file for your unit 8 Reprogram the software by changing the remoteSw...

Page 8: ...8 DRAWINGS AND FIGURES Figure 1...

Page 9: ...9 DRAWINGS AND FIGURES Figure 2 Figure 3 ON OFF Relay Activation Switch...

Reviews: