background image

4

13

200
600

o

o

535

25

1412

1374

520
563

965

1510

200

430

o

Fig. 2

2.4 Safety

2.4.1 Activation

The product is safe to use. It is designed in such a way that 

hazardous parts only occupy restricted areas. Even so, if the 

product is not used correctly or as intended, it may be hazar-

dous to the user or cause damage to the product. The user 

should therefore be informed and trained to handle the 

product’s safety features.

To minimize work-related accidents and injuries during use,

risk reduction has been carried out as follows:

built-in safety

 in the design.

technical protection

 such as barriers, etc.

information for use

 such as user instructions and labels, etc.

 

The product/system may only be used in perfect

 

technical condition and in accordance with the

 

user instructions. Faults that may reduce safety

 

must be eliminated immediately!

 

In addition to the user instructions, national and

 

local safety and accident prevention regulations

 

must be followed when operating the product.

2.4.2 Hazards

 

Note that moving parts in the system always pose

 

a risk (e.g. cutting, clamping or gripping points).

Hose reel ASE 130

Weight*:......................................... 

57 kg

Material cross member: ................. 

Anodised Aluminium

Material other metal:..................... Steel

Material inlet bearing:.................... Plastic

Material outer bearing: .................. Plastic

Colour bracket (Grey): .................... NCS S8502-B

Colour end caps (Blue): .................. NCS S7020-R90B

Max. lifting power: ......................... 30,5 kg

Max. rolled-up hose (Ø200 mm): ... 11 m

Temperature limits

Operating temperature: ................. +5 to +650 

°

C**

Ambient temperature: ................... +5 to +50 

°

C

Transport and storage temp:.......... -20 to +50 

°

C

  * Excluding hose.

  ** Temperature resistance depends on the hose selection. 

   For other temperatures, contact Fumex

2.3 Technical data

Summary of Contents for ASE 130

Page 1: ...MANUAL A18W35_MASE 130_F_EN...

Page 2: ...stallation and startup 4 1 1 Before startup 4 1 2 Assembly and operation 5 Troubleshooting 5 1 Troubleshooting guide 6 Care instructions 6 1 Activation 6 2 Maintenance 6 2 1 Checklist maintenance 7 De...

Page 3: ...val from Fumex This is also applicable to any spare parts used which do not comply with the manufacturer s speci cations Damage that is not due to normal use of the product will result in the warranty...

Page 4: ...nical condition and in accordance with the user instructions Faults that may reduce safety must be eliminated immediately In addition to the user instructions national and local safety and accident pr...

Page 5: ...clip 2 through the holes and around the rubber sheet to lock securely Fig 4 The hose stop should when in the retracted position rest against the drum and t between the end cap and the adjacent hose Ri...

Page 6: ...maintenance may di er The user should therefore determine their own maintenance intervals Please remember that only original spare parts may be used When replacing damaged fasteners only those of ide...

Page 7: ...leaks damage and wear Check the dust build up and clean if necessary Clean the roller externally with a damp cloth Date 6 3 Maintenance 6 3 1 Checklist maintenance 7 Details diagram 1 Shaft extension...

Page 8: ...com info fumex se 8 Accessories ASES 200 ASE 865 AES 200 ASL 200 Automatic mechanical damper Switches to control the fan electric dampers 2 x Hose clamps 1 x Hose AGX 200 length 0 2 m 1 x Hose stop 1...

Reviews: