FUM – 2410/15/20CBP 

 

Introduction 

Congratulations on purchasing our new 3-Stage (IUoU) switching mode battery charger. 

This battery charger is suitable for  wet, sealed (RVLA), calcium-calcium,  gel and  AGM in both car (SLI) and deep cycle type of 
lead acid battery. 

It is a “set and forget” automatic charger which can be permanently connected to battery. 

These models have dual charge banks for charging two batteries simultaneously. 

The special selectable Power Supply mode allows charging battery with external load. 

Intended use: 

All automotive, marine, mobile home, electric scooters, golf carts, solar, deep cycle, UPS standby, industrial & comercial 
applications. 

A.  Control and indicators 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1. Battery charger / power supply selection  

Slide switch to set charger to 3 stage charger or power supply mode (See section G) 

2. Battery type selection  

Slide switch to set charger for AGM/gel, wet and calcium-calcium type battery. 

3. Float voltage selection  

Slide switch to set float charge voltage to 26.4 / 27.0V / 27.6V. 

4. Charge status LED display 

Charger ON LED 

: Green - 3 stage charger mode. // Red - Power supply mode. 

BULK LED(Red) 

: Bulk charging with constant max. current. 

ABSORPTION LED (Orange) 

: Absorption charging with preset constant max. voltage. 

FLOAT LED (Green) 

: Float charging with preset constant voltage. 

5. FAULT LED (Red) 

Charger malfunction (See trouble shooting) 

6. Car blade fuse 

Thermal fuse for reverse polarity protection. 

7. Charging banks 

Screw terminals to connect to supplied charging cable. 

8. Temperature sensor socket 

Connection to optional accessory ATS-5120. 
Sensor to increase / decrease charge voltage at low / high battery temperature. 

9. Remote control socket 

Connection to optional accesory ABD-4120. 
To remote display the charging voltaje & charging status and remote control the charger output ON/OFF. 

Fig.1

Summary of Contents for FUM-2410CBP

Page 1: ...f the charger there is no user serviceable parts inside Do not charge the battery on boats Remove the battery and charge on shore Never attempt to charge a frozen battery Never attempt to charge a damaged battery Wear protective goggles and turn your face away when connecting or disconnecting the battery Never place the charger on top of a battery Never smoke use an open flame or create sparks nea...

Page 2: ... See section G 2 Battery type selection Slide switch to set charger for AGM gel wet and calcium calcium type battery 3 Float voltage selection Slide switch to set float charge voltage to 26 4 27 0V 27 6V 4 Charge status LED display Charger ON LED Green 3 stage charger mode Red Power supply mode BULK LED Red Bulk charging with constant max current ABSORPTION LED Orange Absorption charging with pres...

Page 3: ... Ah C Battery charger installation and connection Observe the warnings safety precautions before rushing to install and operate the charger Check battery condition fill up cells for wet battery clean battery poles Secure the battery charger in a well ventilated place make sure the mounting surface is flat and without soft covering material or loose paper sheet The air intake is at the bottom and a...

Page 4: ...dependently by user according to the type of battery such that battery can be connected permanently to the charger when it is not in use E Manual equalization charging for wet type battery only Wet lead acid battery requires periodic high voltage charging about 10 overcharge absorption voltage to balance the voltage of each cell reverse the high concentration of electrolyte at the bottom and clear...

Page 5: ... voltage However a 2 stage charger cannot completely charge the battery when the charger switches from bulk mode to float mode After switching to float mode the battery will in most cases be about 80 recharged The battery receives the remaining recharge while in float mode over several days It is highly recommended to switch back to the 3 stage charger mode periodically when the external load is d...

Page 6: ...perature control function never plug in the charger during charging I Cable size selection Wire size AWG Area mm Maximum one way distancie for 2 voltage loss 24V 15A Maximum one way distancie for 2 voltage loss 24V 20A Maximum one way distancie for 2 voltage loss 24V 25A 10 5 26 4 65 m 15 3 feet 3 50 m 11 5 feet 2 80 m 9 2 feet 8 8 37 7 31 m 24 feet 5 48 m 18 feet 4 39 m 14 4 feet 6 13 3 11 58 m 3...

Page 7: ...on even after 20 hours charging time Absorption light remains on all the time Wrong battery type selection eg charge gel battery with Calcium Calcium or wet type selection Check charged battery label and change battery type selection to correct setting Total battery capacity is too high for dual charging Check battery capacity or charge battery separately Battery temperature too high Use temperatu...

Page 8: ...ll load 100 230VAC 5 6 2 4A 7 4 3 2A 9 3 3 9A Protection Overload 90 110 rated output current or 50 rated output current soft charge Protection type constant current limiting recovers automatically after fault condition is removed Short circuit Recovers automatically after fault condition is removed Reverse polarity Car blade fuse Over temperature Protecction type shut down OVP output over voltage...