P
age
15
3.
If the set runs more than 60% of its rated capacity, the batteries are good and
the test is complete.
4.
If the set runs less than 60% of its rated capacity, reconnect the discharger.
While under the discharge load, record the end of the discharge voltage for
each battery.
5.
The batteries that are 0.5V lower than the highest end of discharge voltage
should be noted.
6.
If the set delivered less than 60% of its rated capacity, and the same batteries
that were noted in
STEP 3
of
SECTION 6.2
were also the ones noted in
STEP 5
of
SECTION 6.3
, those batteries are most likely failed and should be replaced.
Follow the replacement instructions in
SECTION 6.6
below.
7.
Otherwise, please contact your local Fullriver Battery distributor to review
your data in detail. You can also reach technical support by calling
(800) 522-8191
or emailing
. Additional testing
may be required depending on your specific application.
6.4 - OPTIONAL TEST
After completing
SECTION 6.1
and
SECTION 6.2
, follow these steps:
1.
Operate the vehicle/equipment until battery performance decreases.
2.
Record voltages during and after operation.
3.
Record time and distance of operation.
4.
Provide the voltage, time, and distance data to a Fullriver Battery distributor
or to Fullriver Battery technical support at
(800) 522-8191
or email
5.
This data will be analyzed in comparison to what is expected of the
vehicle/equipment.
6.5 - CCA TEST
(only applicable to Full Throttle series batteries)
1.
Connect and start carbon pile load tester according to CCA rating listed on
battery.
2.
Record all data during test (start voltage, end voltage, pass/fail, tester model,
etc.).
3.
Provide the voltage, time, and tester data to a Fullriver Battery distributor or
to Fullriver Battery technical support at
(800) 522-8191
or email
Testing
Summary of Contents for DC Series
Page 1: ...INSTALLATION AND OPERATION MANUAL ...
Page 4: ...Page d Notes ...
Page 5: ...Page 1 INSTALLATION AND OPERATION MANUAL ...
Page 24: ......