It is to define t he inverter set frequenc y and Acceleration/Deceleration time at Jogging operation.
J ogging operation i s performed by direct start mode and deceleration stop mode.
The Jogging A cce leration ti me is the ti me required for invert er to accelerate from 0Hz to the maximum
output frequency (F0.04).
The Jogging Decelera ti on time i s the t ime re quire d for inverter to decelerate from the ma ximum output
frequency (F0.04) to 0Hz.
W hen the set frequenc y is within t he ski p frequenc y range, the a ctual operati ng frequency will be
operated near the boundary of skip frequency range.
By means of setti ng s kip frequency, the i nverter can keep away from the mechanical resonance point
of the load.
This i nverter has one skip frequency poi nt ava il able. If t hese two skip frequencies are bot h set to 0,
t his function will be i nact ive .
Fig. 6-14 Skip frequency schematic diagram
Sett ing f requency
Skip frequency
1 /2 Skip frequency range
1 /2 Skip frequency range
F4.02
Jogg ing frequency
0.00
F0 .04
~
5.00Hz
F4.0 3
Jogg ing ACCEL time
0.1
36 0.0s
~
10.0s
F4.04
Jogg ing DECEL time
0.1
36 0.0s
~
10.0s
Functio n
Cod e
Name
Setting Range
Default
Value
F4.05
Ski p frequenc y
0.00
F0 .04
~
0.00Hz
F4.06
Ski p frequenc y r ange
0.00
F0 .04
~
0.00Hz
Functio n
Cod e
Name
Setting Range
Default
Value
F4.07
Trav erse frequen cy range
0.0
100.0%
relativ e to se t freq uency
~
(
)
0.0 %
F4.08
Kick frequ ency ran ge
0.0
50.0%(r elativ e to traverse
frequency range)
~
0.0 %
F4.09
Trav erse frequen cy up
time
0.1
360.0s
~
5.0 s
F4.10
Trav erse frequen cy down
time
0.1
360.0s
~
5.0 s
Functio n
Cod e
Name
Setting Range
Default
Value
Chapter 6 Para meter Description
DZB Series
-5 6 -
Ac celerati on/Deceleration time can be chosen to be F0.08, F0. 09 or above three time settings. Their
meanings are all t he same; pl ease refer to F0. 08 and F0.09 related description.
The Acceleration/Decelerat ion time 0-1 at inverter operation can be chosen t hrough di fferent
combination of multifunction digit al i nput termina ls.
F4 Application Func tion Parameters
F3.14
0.00Hz
F3.15
0.0A
F3.16
0.0V
The output frequency when current
fault happens
The output amperage when current
fault happens
The bu s voltage whe n current fault
happe ns
Opera ting frequen cy at
c urrent faul t
Outp ut amperage at
c urrent faul t
Bus voltage at current fault
Function
Code
Nam e
D escription
D efault
Value
F4.00
ACCEL Time 2
0.1
360.0s
~
10.0s
F4.0 1
DE CEL Time 2
0.1
360.0s
~
10.0s
Function
Code
Nam e
S etting Range
D efault
Value
Cha pter 6 Parameter D es cription
DZB Series
F3.17
0.0V
Setting delay ti me(u p)
F3.18
0.0V
Setting unit o f delay time
Function
Code
Nam e
S etting Range
D efault
Value
0~9999
0~3
(0 :fun ction of de lay time invalid)
We also can us e set exter nal terminal fun ction to s et delay time of F3.17 .
Setting uni t o f d elay ti me 0 :delay ti me func tion invalid
1:t he unit of delay tim e is 0. 1s
2:t he unit of delay tim e 1 s
3 :the unit of delay t ime 1min
- 55-
BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT
BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT
BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT
BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT
BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT
BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT