DIGITAL CONTROLLER FOR HEATING OR COOLING
WITH DEFROST AND CONFIGURABLE
ALARM OUTPUT
MT514EV01-02T
-15072
4. INDICATIONS AND KEYS
5. INSTALLATION - ASSEMBLING AND ELECTRICAL CONNECTIONS
1. DESCRIPTION
2. APPLICATION
It is a temperature-based controller designed for cooling or heating applications. It is loaded with one
temperature sensor and two outputs of control, including a SPDT contact that can be used for alarm or
defrost purposes. Defrost can be electric or hot gas. The controller offers a built-in buzzer and a digital
input which can be configured for door alarm or power outage alarm, or detection of both events through
the single digital input. Two configurable preset options is available for quick parameter change. Preset
include variables such as temperature setpoint, differential and cooling time (interval between
defrosts). Other salient features include internal buzzer, IP65 frontal, min-max temperature record,
temperature sensor response-time control, tamper-proof function and control functions shutdown.
Product conforming to UL Inc. (United States and Canada) and NSF
.
(United States)
• Vaccine refrigerators
• Refrigerated counters
• Freezer rooms
• Hot counters
• Greenhouses
evolution
MT-514
e
Ver
.01
Panel (Front View)
Panel
(Side View)
Dimension of the clipping
for fixing of the
instrument in panel
71
mm
± 0,5
29
mm
± 0,5
FOR INSTALLATIONS WHERE A SEALING IS REQUIRED
TO AVOID LIQUID CONTACT, THE CUT FOR THE
CONTROLLER MUST BE OF 70,5X29mm MAXIMUM. THE
SIDE LOCKS MUST BE FIXED SO IT PRESSES THE
RUBBER SEALING AVOIDING INFILTRATION BETWEEN
THE CUT AND THE CONTROLLER.
ATTENTION
1
5 6 7 8
2 3 4
9
POWER
SUPPLY
SENSOR
10 11 12 13 14 15 16 17
REFR
HEAT
RE
FR
115 Vac
1
5 6 7 8
2 3 4
9
POWER
SUPPLY
SENSOR
10 11 12 13 14 15 16 17
230 Vac
Connection
115 Vac
Loads supply
CO
MM
ON
Connection
230 Vac
Loads supply
1
5 6 7 8
2 3 4
9
POWER
SUPPLY
SENSOR
10 11 12 13 14 15 16 17
1
5 6 7 8
2 3 4
9
POWER
SUPPLY
SENSOR
10 11 12 13 14 15 16 17
Connection
12 Vac/dc
12 Vac/dc
24 Vac/dc
Connection
24 Vac/dc
Loads supply
IMPORTANT
SCREWDRIVER SLOT 3/32''(2.4mm) FOR ADJUSTMENTS IN THE
SIGNAL TERMINALS;
SCREWDRIVER PHILLIPS #1 FOR ADJUSTMENTS IN THE POWER
TERMINALS;
WARNING
ACCESSORIES:
Only use original Full Gauge Controls accessories.
If you have any questions, please contact technical support.
AUTHORIZED SERVICE:
The installation or maintenance of the product must be performed by qualified professionals only;
THE USE OF APPROPRIATE TOOLS IS ESSENTIAL TO AVOID
DAMAGE IN THE CONNECTION AT INSTRUMENT TERMINALS:
D1
D1
Control functions
shutdown
Function
blocking
Serial
Programming
Protection
level
Defrost
IP 65
FRONT
Audible
Alarm
AL
RM
/
DE
FR
CO
MM
ON
NO
NC
REFR
HEAT
NO
NC
CO
MM
ON
CO
MM
ON
6. OPERATIONS
6.1. Quick Access Menu Map
To access or browse in the quick access menu, use the
;
key (quick touch) while the temperature is
being displayed by the controller. Each touch displays the next function of the list; for confirming, use
the
/
key (quick touch). For further details, refer to chapter 6.3.
REFR
HEAT
NO
NC
REFR
HEAT
NO
NC
CO
MM
ON
CO
MM
ON
Loads supply
CO
MM
ON
CO
MM
ON
;
;
MT-514
e
MT-514
e
;
DEFROST (ON/OFF)
;
FUNCTIONS LOCKDOWN
;
CONTROL FUNCTIONS
(ON/OFF)
ADJUSTING DESIRED
TEMPERATURE
(SETPOINT)
EXIT FUNCTION
;
FUNCTION SELECTION
;
VISUALIZATION OF
PROCESSES
;
ERASE MIN. AND MAX.
VALUES
MT-514
e
MT-514
e
MT-514
e
MT-514
e
MT-514
e
MT-514
e
MIN. AND MAX.
TEMPERATURE RECORD
;
MT-514
e
MT-514
e
D1
D1
MT-514
e
MT-514
e
/
RE
FR
AL
RM
/
DE
FR
/
RE
FR
AL
RM
/
DE
FR
/
RE
FR
AL
RM
/
DE
FR
/
(*)
This instrument measures and controls temperatures of up to 200°C/392°F, using the silicone sensor cable SB59
(sold separately).
Note:
The sensor cable lenght can be increased by the user up to 200 meters using PP 2 x 24 AWG cable.
3. TECHNICAL SPECIFICATIONS
Control temperature
-50 to 105ºC (-58 to 221°F)*
Power supply
MT-514 E:
115 or 230 Vac ±10%(50/60 Hz)
MT-514 EL:
12 or 24 Vac/dc +10%
Operating temperature
0 to 50 ºC / 32 to 122°F
Operating humidity
10 to 90%RH (without condensation)
Dimensions (mm)
76 x 34 x 77 mm (WxHxD)
Load current (outputs)
OUT1:
16(12)A 250Vac 2HP
OUT2:
10A / 240Vac 1/4HP
Dimensions of the clipping for fixing
of the instrument
71 ± 0,5 x 29 ± 0,5 mm (see item 5)
Set key
Quick Access
Menu Key (Flatec)
Functions lock indication LED
Temperature unit indication LED
Increase key
Decrease key
Alarm indication LED
Cooling indication LED
Heating indication LED
Defrost indication LED
DUE TO YOUR CONSTANT EVOLUTION, THE FULL GAUGE CONTROLS RESERVES THE RIGHT TO
CHANGE THE INFORMATION CONTAINED IN THIS MANUAL AT ANY TIME WITHOUT NOTICE.
BEFORE INSTALLING THE CONTROLLER, WE RECOMMEND READING THROUGH THE
ENTIRE INSTRUCTION MANUAL IN ORDER TO AVOID POSSIBLE DAMAGE TO THE
PRODUCT.
PRECAUTIONS WHEN INSTALLING THE PRODUCT:
Before performing any procedure on this instrument, disconnect it from the mains;
Ensure that the instrument has adequate ventilation and avoid installation in panels containing
devices that may cause it to operate outside the specified temperature limits;
Install the product away from sources that may generate electromagnetic disturbances such as:
motors, contactors, relays, solenoid valves, etc;
6.2 Quick access keys map
When controller is on temperature display mode, the following keys can be used as a shortcut for the
following functions:
Hold down for 2 seconds: Setpoint adjustment.
Quick touch: Current process display.
Quick touch: Maximum and minimum temperature display.
/
<
<
<
Hold down for 2 seconds: Inhibit audible alarm (buzzer).
Have this manual in the palm of
your hand by
FG Finder
application.
E251415