KNOW YOUR PRODUCT
PRE-OPERATION CHECK (cont.)
Upper
level
allowed
OFF
RUN
CHOKE
91 RON
Unleaded
Petr
ol
Upper
level
allowed
OFF
RUN
CHOKE
91 RON
Unleaded
Petr
ol
Fig. 4
Fig. 5
1.
Switch off engine by moving the engine control
switch (5) to the OFF position (fig. 4). Make sure that
the inverter generator is on a level surface.
2.
Remove the fuel cap (1) by rotating in a anti-
clockwise direction.
3.
Visually check the fuel level and, if necessary, add
fuel to the tank (91 RON Unleaded Petrol) (fig. 5).
Do not overfill the fuel tank. Do not use ethanol
blended fuels (Fuel tank capacity 12 litres).
4.
After refuelling, make sure the fuel cap (1) is fitted
properly and securely.
WARNING!
Keep away from cigarettes, smoke and sparks when refuelling
the inverter generator. Always refuel in a well-ventilated location.
WARNING!
Do not over fill the fuel tank.
WARNING!
Be careful not to spill fuel when refuelling. Spilled fuel or fuel
vapour may ignite. If any fuel is spilled, make sure the area is dry before
starting the engine.
WARNING!
Never refuel the inverter generator while the engine is
running and always allow the engine to cool before refuelling.
Refuelling the generator
WARNING!
Never operate the inverter generator in an enclosed area.
Engine exhaust contains carbon monoxide. Only operate the inverter
outside and away from windows, doors and vents.
Grounding
Consult with your local municipalities for your grounding codes.
The generator’s ground terminal (21) must always be used to connect the
generator to a driven ground rod. Connect the ground terminal (21) to the driven
ground rod with copper wire. The wire connects to the terminal between the lock
washer and nut. Tighten the nut securely to ensure good connection. Grounding
the generator protects you from electric shock that results from a build up of static
electricity or undetected ground faults.
WARNING!
Be sure the inverter is properly connected to earth ground
terminal (21) before operating.