17
Cleaning
• Keep all safety devices, air vents and the motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean cloth or blow it with compressed air at low
pressure.
• We recommend that you clean the device immediately each time you have finished
using it.
• Clean the equipment regularly with a moist cloth and some soft soap. Do not use
cleaning agents or solvents; these could attack the plastic parts of the equipment.
• To maintain the life of the water pump (13), clean with fresh water after every use.
Maintenance
• There are no parts inside the equipment which require additional maintenance.
• Lubricate all moving parts at regular intervals.
• Clean off any soiling on the trough (3) and cooling water pump (13) at regular intervals,
otherwise the diamond cutting wheel (2) may not be cooled as required.
• At regular intervals the trough water must be replaced. Start by removing the work table
assembly from the trough (3) and proceed to replace the dirty water with clean water.
Ensure the trough is free from debris
Laser
•. Dismantle the laser before you clean machine with water.
Transport
• The water must be drained completely before transport.
• Do not lift the machine by any of the safety devices.
• T
he cutting length adjustment knobs (25) on the guide rail (7) can be used to fix the
machine head (24) in place while transporting the unit.
• Use the transport spacer (31) to fix the machine head
(24) to the side of the tile cutter that has the angle scale
(17) (Fig. 29). This will ensure that the machine head
remains stable during transport.
Fig. 29
MAINTENANCE