External surface area example 4
open side for at least 25% of the
total area of the walls
in total 30% or more of the remai-
ning surface of the walls is open
and free
External surface area example 5
open side for at least 25% of the
total area of the walls
in total 30% or more of the remai-
ning surface of the walls is open
and free
Selection of the point of installation
•
The appliance must not be installed on combustible materials. The minimum distance from
combustible materials is 600 mm.
•
The free space above the cooking surface with respect to combustible materials must be at
least 600 mm.
•
The appliance must be installed in accordance with standards and local deviations.
•
When using LPG, ventilation must be ensured in the compartment. The gas is highly
explosive and can cause serious personal injury and property damage if it is left to
accumulate and then ignited.
•
The barbecue is designed to be mounted in a counter with a minimum depth of 600 mm.
•
Avoid locations exposed to the wind as this may affect cooking and the efficiency of the
burners. If you cannot avoid such a location, screens may be necessary.
Installation compartment
•
The barbecue requires a non-combustible barrier beneath it to prevent reaching an
excessive temperature in compliance with the current UNI EN 498 standard. The panel that
acts as a barrier must be positioned 30 mm below the base of the unit.
•
The installation compartment must be made of non-combustible materials. Materials suitable
for its construction include brick, granite, marble, Hardiplank® and Villaboard® on a metal or
brick structure.
Summary of Contents for SUPREME OUTDOOR SBQ 1000 G
Page 1: ...SUPREME OUTDOOR SBQ 1000 G ...
Page 2: ......
Page 20: ...20 I DETTAGLIO A RETRO RETRO FRONTE FRONTE ...
Page 23: ...23 I Dettaglio di allacciamento del gas 50 490 45 EN 10226 1 EN 10226 2 EN ISO 228 1 ...
Page 24: ...24 I Con nota collegamento gas naturale GN ...
Page 30: ...30 I 505 177 Parete Top 70 10 0 55 5 10 0 FRONTE ...
Page 34: ...34 I min 300 mm MAX 1 5 mt min 300 mm 210 mm ...
Page 36: ...36 I ...
Page 40: ...40 I A DETTAGLIO A ...
Page 62: ...62 GB 3 Apply the oil drip pans to the front of the barbecue BACK BACK FRONT ...
Page 69: ...69 GB DETTAGLIO A BACK BACK FRONT FRONT ...
Page 72: ...72 GB Detail of the gas connection 50 490 45 EN 10226 1 EN 10226 2 EN ISO 228 1 ...
Page 73: ...73 GB With note natural gas connection NG ...
Page 79: ...79 GB 505 177 Parete Top 70 10 0 55 5 10 0 FRONT Wall ...
Page 83: ...83 GB min 300 mm MAX 1 5 mt min 300 mm 210 mm ...
Page 85: ...85 GB ...
Page 89: ...89 GB A DETTAGLIO A DETAIL A ...
Page 102: ...102 GB ...
Page 103: ......