Error code
description
Possible causes
Error recovery
E/3
Unsustable pot, e.g.
lost of the magnetic
characteristics because
of temperature in the
bottom.
Pot creates on the
modul an improper
operating point which
can destroy devices,
e.g. IGBT.
1. the error is
automaticly cancelled
after 8s and the cooking
zone can be used
again. In case of further
upcoming errors the post
have to be changed.
2. the modul has to be
changed if the error
comes without an pot on
the cooking zone.
E/4
Unconfigured induction
modul (all induction
modul answer to UI, but
any element is related
to the effected cooking
zone).
Induction modul is not
configured.
1. Delet the hob
configuration and
activate the manual
configuration.
2. Start the UI service
menue to configure the
imduction modul.
3. If the listed points are
not succesful replace
the modul.
E/5
No communication
between UI and
inducation modul.
No power supply of
induction modul
Mal cabeling or defect
of.
Check power and lin
connections is the
connention ok, replace
the modul.
E/6
Main power disturbace .
1. Failure in main power
frequency detection.
Check main power
voltage and frequency,
if ok.