TROUBLE SHOOTING (CONTINUED)
26
Error
Cause & Solution
Laser Will Not
Self-Level
Outside Levelling Range Or Impact Damage
If the FRE-205 is positioned outside of it’s self levelling range of
±5 degrees the rotating laser prism will tilt over to one side (to
try and locate a level position) and then time-out.
Re-position the FRE-205 so that is is within ±5 degrees of level
and try again.
If it’s within ±5 degrees of level and the prism remains tilted over
to one side, turn the laser OFF and On again and try again. If the
laser will still not self level, it may have received an impact which
has aff ected the self levelling system. Try the Factory Reset pro-
cedure on page
23
. If that also fails, please contact the Service
Department:
08000 869 769
who will be able to how to send it
for repair.
Laser Not Holding It’s
Charge
Battery Issue
Check the rechargeable batteries. The rechargeable batteries
may require charging or need to be replaced due to age and/or a
high number of charging cycles.
Check the battery compartment for signs of damage and ensure
that the compartment is clean and that the battery terminals are
not corroded.
Detector Not Detect-
ing The Laser Beam
Multiple Causes
Check the battery in the detector. They may be low and need
replacing.
Check the FRE-205 is spinning and producing a visible red beam.
You will be able to see the beam on your hands when placed in
front of the protective lighthouse.
Check the line of sight and ensure there is no obstructions.
Check that the laser level and detector are within the operat-
ing range. If you are too close to the laser it may not pickup the
beam. You need to be at least 3m away.
Check that the protective lighthouse glass is clean and free of