background image

Horizontal Beam Out-of-Plane Tilt (FIG. 2)

Position the instrument parallel to a wall and project a beam along the wall, from  

left to right as shown. Mark two locations (

a

b

) along the beam separated by distance 

x

Position the laser at the other side of the wall and project the beam back through mark 

b

, from right to left as shown, and mark position 

c

. If x is 30' (9.1 m), then the vertical 

distance 

d

 should be ≤ 5/32" (4 mm). For example, if 

x

 is set to 15' (4.6 m), then the 

vertical distance 

d

 should be ≤ 3/32" (2 mm).

Horizontal Beam Left/Right Tilt (FIG. 1)

Secure instrument via its mounting bracket at a distance 

x

 from a vertical wall 

structure as shown. Rotate the instrument on the bracket to the left so that the right 

side of the beam is projected  

on the wall directly across  

from the instrument, mark  

the vertical location on the  

wall. Rotate the instrument  

to the right and repeat  

marking the vertical location  

of the left side of the beam.  

At ~33' (10 m) the vertical  

distance 

d

 between the  

left-side and right-side 

markings should be ≤ 5/32" (4 mm).  

For example, if 

x

 is set to 15' (4.6 m),  

the vertical distance 

d

 should be ≤3/32" (2 mm).

FIG. 2

d

a

b

c

x

W

ALL

W

ALL

FIG. 1

WALL

Vertical distance 

between markings

Right

Left

d

L

L

x

R

R

R

Vertical Beam Tilt (FIG. 3)

Position the instrument on the floor and project a vertical beam along a line 

x

 of 

about 6' (1.9 m). Mark point 

on the ceiling. Position the instrument on the other 

side of the line and repeat marking point 

b

 on the ceiling. The distance 

d

 should be 

≤5/32" (4 mm) for a 33' (10 m) ceiling or ≤3/32" (2 mm) for a 15' (4.6 m) ceiling. 

FIG. 3

x

d

a

W

ALL

W

ALL

CEILING

Plumb Spot (Model 93LCLS Only, FIG. 4)

Position instrument on the floor and 

project a spot with the plumb spot laser  

to the ceiling. Rotate the laser by 180

°

 and 

project the exact same spot to the ceiling. 

The distance 

d

 should be ≤1/4" (6mm) for 

a 33' (10m) ceiling or ≤1/8" (3mm) for a 

15' (4.6m) ceiling.

d

FIG. 4

b

180°

VERIFYING ACCURACY OF LASER LINES

93LCL

  Self-Leveling Cross Line Laser Level

93LCLS

  Self-Leveling Cross Line Laser Level with Plumb Spot

Reviews: