Bright LED's next to the green pick-up window show above/below or SET
LEVEL.
Both side & rear LED's simply repeat the main front display.
Use with or without its staff mounting bracket. Spare brackets are available.
How to use the Detector:
SWITCH
ON the EK-268G's button marked *OUTDOOR.
Face the detector towards the laser & find the centreline of the laser beams
via the green pick-up window. Obtain a continuous tone for true level. Mark
out.
Outdoor use
....
If the sun is low in the sky & shining into the green window, shield it with a
cupped hand to prevent false readings. Positioning the laser level itself in full
sun is no problem but the detector window can in some instances, be affected
by direct bright sunlight or reflections from glass or water.
So please take extra care!
Important
Only switch on the Outdoor button when you need a "pulsed output" to
operate the detector. This will save battery power & make the normal green
laser lines brighter - for general use.
SAFETY PRECAUTIONS:
Comply with class 3R laser operating safety procedures.
Display a
Laser Safety Notice
in the working area.
General Advice:
This is an accurate measuring device - so to give good service, look after it!
Prevent the EK-268G from receiving severe knocks, bangs or vibration.
Store the laser & its accessories in the supplied, foam-lined carry case.
If wet, dry before storing & keep in storage temperatures between 5 - 25 deg
C.
For long-term storage, remove the Li-on battery - to prevent any internal
damage.
There are NO User serviceable parts.
4