background image

Thank you for purchasing the TOPCON RL-H3CS Rotating Laser.
The RL-H3CS instrument has many unique features. For basic operation, rough level the instrument and  press power  switch. It
will self-level, then emit a rotating laser beam to create a level reference plane. The laser provides controls that allow the beam
plane to be tilted up to 5 degrees for single slope applications.
For superior product performance, please read these instructions carefully and keep them  in a convenient place for future reference.

GENERAL HANDLING PRECAUTIONS

Before star ting work or operation, be sure to check that the instr ument is functioning correctly with nor mal performance.

When storing the instrum ent for long period, remove the batteries.
Always make sure instrument is dr y before putting it in the carrying case. Never store a damp instrument. 

DISPLAY FOR SAFE USE

In order to ensure the safe use of this  product, prevent any  danger to the operator  or others, or damage to property, important war nings 

are

placed on the product and inserted in the instruction manual. We rec ommend that you become familiar with the meaning of these Wa

rnings

and Cautions before continuing.

INSTRUCTION MANUAL

ROTATING LASER

RL-H3CS

•Injury refers to hurt, burn, elec tric  s hock, etc.
•Physic al damage refers to extensive damage to equipment and structure or furnishi ngs.

Display

Meaning

WARNING

Ignoring or disregard of this display may 
lead to the danger of death or serious inju-
ry.

CAUTION

Ignoring or disregard of this display may 
lead to personal injury  or  physical  damage.

CAUTION

• Use of controls or adjustment or performance of procedures other than those spec-

ified herein may result in hazardous radiation exposure.

• Do not stand or sit on the carrying cases. 

It could overturn, causing injury.

• Do not use a damaged instrument case. 

It could accidentally open causing damage to the instrument or injury to people.

• Do not place yourself or a reflecting object in the path of the laser beam. If using the 

laser outside, avoid positioning it anywhere near eye level to avoid any possibility of 
it striking someone in the eye. If this should happen, visibility could be temporarily 
impaired, causing disorientation and possible accidental injury.

• Please note that the tips of tripod can  be hazardous, be aware of this when setting 

up or carrying the tripod.

• Do not allow skin or clothing to  come into contact with acid from the batteries, if this 

does occur then wash off with copious amounts of water and seek medical advice.

• Do not place instrument on unstable platform, surface or tripod.

If  using tripod,  make sure instrument is securely attached.

• Risk of injury by falling down a tripod  and an instrument.

Always check that the screws of tripod are tightened.

Exceptions from Responsibility

1

The user of this  product  is expected to follow  all  operating instructions  and make periodic  checks of the  product’s performance.

2

The manufacturer, or its representatives, assumes no responsibility for results of a faulty or intentional usage or misuse inclu ding any direct, indirect, conse-
quential  damage, and  loss of  profits.

3

The manufacturer, or its representatives, assumes no responsibility for consequential damage, and loss of profits by any disaste r, (an earthquake, storms, 
floods etc.), fire, accident, or an act of a third party and/or a usage in other than usual conditions.

4

The manufacturer, or its representatives, assumes no responsibility  for  any  damage, and loss  of profits due to a change of data, loss of data, an interruption 
of business etc., caused by using the product or an unusable product.

5

The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits caused by usage other th an explained in the user 
manual.

6

The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong movement, or action due to connecting with other products.

STANDARD PACKAGE COMPONENTS

Upon opening, make sure that all the followings are included.

1 RL-H3CS Instr ument . . . . . . . . . . . . . . . . . . . . . . . . 1set
2 LS-70B Laser Sensor  . . . . . . . . . . . . . . . . . . . . . . . 1set
3 Size "C" dry batteries (R14PU) . . . . . . . . . . . . . . . . 4pc.
4 9 volt dr y batter y (6F22/S-006P) . . . . . . . . . . . . . . . 1pc.
5 Carrying case  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1pc.
6 Instruction manual . . . . . . . . . . . . . . . . . . . . . . . . . . 1vol.
7 Model-6 Laser Sensor Holder  . . . . . . . . . . . . . . . . . 1pc.

Detect the on-grade position  “---” by moving the Laser Sensor
up and down. Directional arrows and audio signals assist in 
locating the on-grade position as the laser strikes the beam 
receiving window.  (Top of Laser Sensor is 40mm (1 9/16") 
from on-grade index for offset marking.) 

LS-70B:The indicators are located on front and back sides of the
              instrument.

Indicator

On-Grade precision switch

Two on-grade precision options are available, normal  preci-
sion and high precision. By pressing this switch, the preci-
sion options are switched alternately . Confirm the precision 
choice by the indicator. (Normal precision is the default set-
ting each time the sensor is turned on. See LS-70B Indica-
tor diagram below.)

The power switch turns ON or OFF by pressing. If the power 
switch is turned ON, all signs will be displayed on the indica-
tor for a second with a beep sound.

Volume of the sensor buzzer can be alternately switched to
LOW/LOUD/OFF by pressing the switch.

Auto shut off function

The power will be turned off automatically if no laser beam 
is detected for approximately 30 minutes. (To turn on the 
laser sensor, press the power switch again.)

Power switch

Buzzer speaker

Buzzer sound switch

Beam receiving window

On-Grade
Index

LS-70B

(Laser Sensor)

RL-H3CS

Turn the beam receiving window side 
towards RL-H3CS to detect the laser beam.

Protective glass

Rotary head

Laser beam emits from here.

Handle

Battery door

Battery door knob

Power switch

Turn the instrument ON or OFF.

Laser Safety

This product uses a visible laser beam, and is manufactured and sold in accordance with “Perfor mance Standards for Light-Emittin g Products”
(FDA/BRH 21 CFR 1040) or “Radiation Safety of Laser Products, Equipment Classification, Requirements and User’s Guide” (IEC Publication
60825-1) provided on the safety standards for laser products.
As per the said standard, this product is classified as a  “Class ll Laser Product” or “Class 2 Laser Product”.
This is a simple product to operate and does not require training from a laser safety officer.
In case of any failure, do not disassemble the instrument. Contact TOPCON or your TOPCON dealer. 

Beam aperture

NOMENCLATURE AND FUNCTIONS

Battery power (Red LED)

Blinking:
The power is low, but laser is still usable. (Blinking 
continues for one minute.)
On Solid:
Dead batteries. Replace the batteries with  new 
ones. (The lamp is solid for five minutes, then turned 
off automatically.)

Auto leveling (Green LED)

Blinking quickly:
Auto leveling is in process.
Blinking slowly:
Auto leveling is almost complete.
On Solid:
Auto leveling is complete.

Manual mode ON switch

ON:Push twice continuously.
OFF:Push once.

Height alert OFF switch

OFF:Push twice continuously.
ON:Push once.

Height alert OFF (Red LED)

Height alert does not function.

Manual mode ON (Red LED)

Auto leveling does not function.

Label

SAFETY CAUTIONS

WARNING

• There is a risk of fire, electric shock or physical harm if you attempt to disassemble 

or repair  the instrument yourself.
This is only to be carried out  by TOPCON  or an authorized dealer, only !

• May ignite explosively.

Never use an instrument near flammable gas, liquid matter, and do not use in  a  coal mine.

• Cause eye injury or blindness.

Do not stare into  beam.

• Risk of fire or electric shock.

Do not use a wet battery.

• Battery can cause explosion or injury.

Do not dispose in fire or heat.

•The short circuit of a battery can cause a fire.

Do  not short circuit  battery when  storing it.

CLASSII LASER  PRODUCT

DIODE LASER 

WAVE LENGTH 630-685nm

1mW MAXIMUM OUTPUT

C A U T I O N

LASER RADIATION

DO NOT STARE INTO BEAM

CLASS

 

2

@

LASER PRODUCT

DO NOT STARE INTO BEAM

LASER RADIATION

Note
In manual mode

•Auto-leveling function is not active.
•Height alert function is not active.
•Setting slope function is not active.

Height alert function
(Safety lock system)

When auto-leveling and height 
alert function are active, after the 
laser beam emits for one minute, 
this function prevents the instru-
ment from operating if  it is dis-
turbed. This insures accurate 
control. If the unit is disturbed, 
manual mode ON lamp, height 
alert OFF lamp and auto leveling 
lamp will blink simultaneously. The 
elevation (height of instrument) 
should be verified and re-estab-
lished if  necessary. This function 
is not active in the manual mode.

(1 9/16")

1

Remove the battery cover by turning battery cover knob to “OPEN” side.

2

Remove the batteries by pulling out the slide plate.

3

Install the new  batteries referring to the illustration on the battery 
cover.*1, *2, *3

4

Install  the  battery cover. By  using    a coin,  tighten the battery  cover knob 
to “CLOSE” side until  the knob does not turn.*4

*1 Replace all 4 batteries with new o n es at   t he same time. Do not   mi x used and new batteries, 

and do not mix different types of batteries together.

*2 Use alkaline dry c ells. (Dry   cells for movement confirmation are packed in s hipment.)

Nickel hydrogen dry c ells and nickel cadmium dry  cells c an be used too, but the operating time 
is different from the time of alkaline dry cells.  

*3 Generally, performanc es  of dry cell deteriorate temporarily in low temperature, but recover in 

normal temperature.

*4 It is important to use a coin or other tool to make sure cover is firmly closed to seal out water.

Slide plate

RL-H3CS

1

Press the lid in the direction of the arrow to lift.

2

Remove the battery and replace with a new 9v alkaline 
battery.

3

Press the  lid down and  click to  close.

Laser Sensor

BATTERY REPLACEMENT

STORAGE PRECAUTIONS

Always clean the instrument after use.
Use a clean cloth moistened with neutral detergent or water.
Never use an abrasive cleaner, ether, thinner benzene, or other solvents.
Always make sure the instr ument is completely dr y before storing. Dr y any moisture with a soft, clean cloth.

Slope lamp (Green LED)

Red:Error

Slope key

Tilts beam plane in direction of 
arrow

Sight

Reviews: