Use the table below to determine operation errors indicated by blink ing lamps on the control panel.
If corrective action listed does not correct error, please contact your local Topcon dealer.
Operating procedure
(Setting slope)
Key
operation
Lamp display
(Refer to the right illustration)
1
Press Power switch ON.
You can set the slope after auto-leveling is completed.
Power switch
D uring auto-leveling : Lamp B (Green) blinks.
After auto-leveling is completed. : Lamp B (Green) lights.
2
Press either Slope key once. The laser beam begins
to move in the direction of the arrow on the key.
After auto-level-
ing is completed.
Slope key
Lamp E (Green) blinks quickly.
3
Press Slope key again to stop the laser beam.
Slope key
Lamp E (Green) lights.
4
Press Slope key to fine adjust the slope.
Beam movement begins slowly, then increases
depending on how long the Slope key is pressed.
The blinking speed of the lamp provides a visual indi-
cation of the beam movement speed.
Slope key
When Slope key is not pressed: Lamp E (Green) lights.
Slope key Lamp E (green) Beam movement
Press for a shorter time : Blinks slowly : Moves slowly
↓
↓ ↓
Press for a longer time : Blinks quickly : Moves quickly
5
Press Power switch OFF to cancel the slope setting.
Power switch
All lamps are OFF.
Operating procedure
(Recalling slope)
Key
operation
Lamp display
(Refer to the right illustration.)
1
To recall the previous slope setting (the setting before
power was OFF), press Power switch ON while press-
ing either the right or left Slope key. The slope can
then be adjusted as described in step
4
above.
•
When the Power switch is ON without the Slope key
pressed, the laser beam will return to level.
Slope key
+
Power switch
When Slope key is not pressed: Lamp E (Green) lights.
Slope key Lamp E (green) Beam movement
Press for a shorter time : Blinks slowly : Moves slowly
↓
↓ ↓
Press for a longer time : Blinks quickly : Moves quickly
CHECKS AND ADJUSTMENTS
Checking and adjusting calibration
Checking cone error
Error Code
1
Horizontal calibration of the laser beam can be checked by the user.
[Checking]
1
Set up a tripod approx. 50m (160ft) from a wall. Mount the instrument on the
tripod, facing the X1 side toward the wall.
2
Turn the instrument on and allow auto-leveling to complete.
3
Put the laser sensor in fine detection mode by pressing the On-Grade preci-
sion switch.
4
By using the laser sensor, mark the center position of laser beam on the wall.
(X1)
5
Turn off the instrument.
Loosen the tripod screw, rotate the instrument 180 degrees and re-secure it
on the tripod. The X2 side of the instrument faces toward the wall.
When rotating the instrument, avoid changing the height.
6
Turn the unit on again and allow auto-leveling to complete.
7
By using the laser sensor, mark the center position of laser beam on the wall.
(X2)
8
If the difference value of marked two laser beam heights (difference value of
X1 and X2) are less than 7mm, adjustments are not needed. The difference
value is greater than 7mm, adjust the instrument as described in right. *
9
Check the X1 (handle) side as the same way.
X1
X2
[To calibrate the X axis ]
1
Face the X1 side of the instrument (panel side) toward a wall, press the Power
switch while pressing the height alert OFF switch.
Then the height alert OFF lamp will light, and manual mode ON lamp will blink.
2
Press the height alert OFF switch to calibrate the X axis. The manual mode
ON lamp will light. When auto-leveling finishes, the laser beam will emit.
3
Using the laser sensor, mark the on-grade height of laser beam on a wall.
4
Rotate the instrument 180 degrees to face X2 side toward a wall.
5
In the same way as step 3 , mark the on-grade height of laser beam on a wall.
6
By pressing the manual mode ON switch (laser beam moves up), or Power
switch (laser beam moves down), adjust the on-grade height of the beam until
it is precisely centered between the marks made in steps 3 and 5 .
7
Press the height alert OFF switch to memorize the new laser beam calibration.
The height aler t OFF lamp will blink. Power will shut off automatically when the
calibration memorization is complete.
[To calibrate the Y axis ]
1
Face the Y1 side of the instrument (handle side) toward a wall, press the
Power switch while pressing the height alert OFF switch.
Then the height alert OFF lamp will light, and manual mode ON lamp will blink.
2
Press the Power switch again. The auto leveling lamp will light.
3
Press the height alert OFF switch to calibrate the Y axis. The auto leveling
lamp will light.
4
Using the laser sensor, mark the on-grade height of laser beam on a wall.
5
Rotate the instrument 180 degrees to face Y2 side toward a wall.
6
In the same way as step 4 , mark the on-grade height of laser beam on a wall.
7
By pressing the manual mode ON switch (laser beam moves up), or Power
switch (laser beam moves down), adjust the on-grade height of the beam until
it is precisely centered between the marks made in steps 4 and 6.
8
Press the height alert OFF switch to memorize the new laser beam calibration.
The height aler t OFF lamp will blink. Power will shut off automatically when the
calibration memorization is complete.
*If the difference value is greater than 60mm (2 3/8 inches), contact your
Topcon dealer.
laser sensor
Wall
Approx. 50m
X1 Laser beam
Laser point of X1
Approx. 50m
X1
X2
X1
To discontinue calibration the instrument, press the Power
switch while pressing the height alert OFF switch.
Y1
Y2
[Checking]
1
Set up the laser centered between two walls approximately 40m (131ft) apart. Orient the instrument
so one axis, either X or Y, is facing the walls.
2
Locate and mark the position of the rotating laser beam on both walls using the laser sensor.
3
Turn off the instrument and move the instrument closer to wall A (1m to 2m /3 ft to 6 ft).
Do not change the axis orientation of the instrument. Turn the instrument on.
4
Again locate and mark the position of the rotating laser beam on both walls using the laser sensor.
5
Measure the distance between the first and second marks on each wall.
If the difference between each set of marks is less than 4mm (5/32 of an inch), no error exists.
Perfor m the following check after com pleting horizontal calibration procedure.
Cone error
Datum position
2
3
Lamp Indication
Error Code
Corrective Action
Lamp B, C and D blink in turn
Auto-leveling range
error
Correct tilt of the instrument until it less
than 3 degrees.
Lamp A lights
Batter y power error
Replace all 4 batteries with new ones at
the sam e time.
Lamp B, C and D blink simulta-
neously
Height alert error
Turn power off, rough level the instrument,
then turn power on again. Check height of
laser beam as it may have changed.
Lamp D blinks quickly
Calibration error
Repeat calibration procedure. If error re-
peats contact your local Topcon dealer.
Lamp E(Red) lights
Lamp B, C and D blink in turn
Slope setting range
error
Push the slope key of the opposite side,
and align slope.
Lamp A, B, C and D blink si-
multaneously
Internal error
Turn power off, then on again. If error re-
peats contact your local Topcon dealer.
A
B
D
C
LS-70B
Beam detection window
: 50mm (2.0 in)
Beam detection precision
: High precision : ±1mm(±0.04 in)
: Normal precision : ±2mm(±0.08 in)
Beam detection
indication
: Liquid crystal and buzzer
Power source
: DC 9V alkaline (dry) battery
Operating time
: Approx. 80 hours at +20°C (+68°F)
(Using alkaline manganese dry batteries)
Auto shut-off delay
: Approx. 30 minutes without beam detection.
Operating temperature
: -20°C~+50°C (-4°F~+122°F)
Dimensions
: 165(L)x78(W)x26(H)mm
(6.5x3.0x1.0
in)
Weight
: 0.25 kg [0.55 lbs] (With dry batteries)
SPECIFICATIONS
RL-H3CS
Accuracy
: ±3.6mm/50m (±15 ”)
Automatic correction range + Setting slope range : ±5°
Beam detecting range
: Approx. 2m~300m (6ft~980ft) diameter
Rotational speeds
: 600r.p.m
Laser source
: Laser diode (Visible, Red)
Laser power output
: 0.8mW (Max.)
Laser class
: Class 2 laser product
Power supply
: Four C size alkaline
manganese dry batteries
Operating time
: Approx. 60 hours at +20°C (+68°F)
Protection against
water and dust
: IP56
(Based on the standard IEC 60529)
Operating temperature
: -20°C~+50°C (-4°F~+122°F)
Dimensions
: 167(L)x182(W)x193(H)mm
(6.5x7.1x7.6 in)
Weight
: 1.9kg[4.1lbs] (With dry batteries)
X2 Laser beam
Wall A
Wall B
Wall A
Approx. 40m
*If the difference value is greater than 4mm(5/32 inch), contact your Topcon dealer.
When calibration is memorizing, if the height alert lamp
continues to blink quickly and power does not shut-off auto-
m atically, please contact your local Topcon dealer.
HOW TO OPERATE
1
Set the instrument to the tripod or smooth surface.
2
Make sure instrument is roughly level.
3
Press power switch (ON).
4
Press power switch on laser sensor (ON).
5
Select the precision mode by pressing the
On-Grade precision switch.
6
Locate the on-grade position “---” by moving
the laser sensor up and down.
7
Mark the position of On-Grade index.
(Top of the Laser Sensor is 40mm [1 9/16"] from
index for offset marking.)
LS-70B Indicator
High precision mode
Normal precision mode
Battery remaining display
Below grade indicator
Move the sensor up.
Audio signal:Lower pitch, slower frequency
Above grade indicator
Move the sensor down.
Audio signal:High pitch, frequent beep
When using the Laser
Sensor with other
select Topcon lasers,
these symbols alert
user if laser batteries
are low or if laser has
been disturbed.
These symbols are
not active when used
with RL-H3CS.
Aligning Direction of Slope
When using the laser to set the slope, the laser
must be properly aligned so the slope axis of the
laser beam is parallel to the desired direction of
slope.
The sight on top of the instrument is calibrated to
the slope axis of the laser beam. Follow the
steps below to align the laser to the desired
direction of slope:
1
Establish a target line parallel to desired
direction of slope.
2
Set up the laser over this line (drop a plumb
bob from the tripod mounting screw).
3
Rough align the instrument to the direction of
slope. Make sure it is properly oriented for the
slope to be set.
4
Using the sight, position the instrument so the
sight is centered on the target. (see illustra-
tion at right)
On-Grade position
Audio signal:Continuous beep sound
[Setting slope]
Manual mode can be activated
while the slope is set.
For information about Manual
mode ON/OFF, refer to "NOMEN-
CLATURE AND FUNCTIONS".
Check the beam often during
slope use for slope accuracy.
Check instrument calibration peri-
odically (see belo w).
E
Target
Wall B
TOPCON CORPORATION
75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
Phone: 3-3558-2520 Fax: 3-3960-4214 www.topcon.co.jp
TOPCON POSITIONING SYSTEMS, INC.
5758 West Las Positas Blvd., Pleasanton, CA 94588, U.S.A.
Phone: 925-460-1300 Fax: 925-460-1315 www.topcon.com
TOPCON CALIFORNIA
3380 Industrial Blvd, Suite 105, West Sacramento, CA 95691, U.S.A.
Phone: 916-374-8575 Fax: 916-374-8329
TOPCON MIDWEST
891 Busse Road, Elk Grove Village, IL 60007, U.S.A.
Phone: 847-734-1700 Fax: 847-734-1712
TOPCON EUROPE B.V.
Essebaan 11, 2908 LJ Capelle a/d IJssel, The Netherlands.
Phone: 010-4585077 Fax: 010-4585045 www.topconeurope.com
TOPCON BELGIUM
Preenakker 8, 1785 Merchtem, Belgium
Phone: 052-37.45.48 Fax: 052-37.45.79
TOPCON DEUTSCHLAND G.m.b.H.
Weidkamp 180, 45356 Essen, GERMANY
Phone: 0201-8619-100 Fax: 0201-8619-111 [email protected]
www.topcon.de
TOPCON S.A.R.L.
89, Rue de Paris, 92585 Clichy, Cedex, France.
Phone: 33-1-41069490 Fax: 33-1-47390251 [email protected]
TOPCON ESPAÑA S.A.
HEAD OFFICE
Frederic Mompou 5, ED. Euro 3, 08960, Sant Just Desvern Barcelona, Spain.
Phone: 93-473-4057 Fax: 93-473-3932 www.topconesp.com
MADRID OFFICE
Avenida Burgos, 16E, 1∞28036, Madrid, Spain.
Phone: 91-302-4129 Fax: 91-383-3890
TOPCON SCANDINAVIA A. B.
Neongatan 2 S-43151 Mölndal, SWEDEN
Phone: 031-7109200 Fax: 031-7109249
TOPCON (GREATBRITAIN) LTD.
HEAD OFFICE
Topcon House Kennet Side, Bone Lane, Newbury, Berkshire RG14 5PX U.K.
Phone: 44-1635-551120 Fax: 44-1635-551170
[email protected] [email protected]
TOPCON SOUTH ASIA PTE. LTD.
Blk 192 Pandan Loop, Pantech Industrial Complex, #07-01, Singapore 128381
Phone: 62780222 Fax: 62733540 www.topcon.com.sg
TOPCON AUSTRALIA PTY. LTD.
408 Victoria Road, Gladesville, NSW 2111, Australia
Phone: 02-9817-4666 Fax: 02-9817-4654 www.topcon.com.au
TOPCON INSTRUMENTS (THAILAND) CO., LTD.
77/162 Sinn Sathorn Tower, 37th Fl.,
Krungdhonburi Rd., Klongtonsai, Klongsarn, Bangkok 10600 Thailand.
Phone: 662-440-1152~7 Fax: 662-440-1158
TOPCON INSTRUMENTS (MALAYSIA) SDN. BHD.
Excella Business Park Block C, Ground & 1st Floor, Jalan Ampang Putra,
Taman Ampang Hilir, 55100 Kuala Lumpur, MALAYSIA
Phone: 03-42701068 Fax: 03-42704508
TOPCON KOREA CORPORATION
2F Yooseoung Bldg., 1595-3, Seocho-Dong, Seocho-gu, Seoul, 137-876, Korea.
Phone: 82-2-2055-0321 Fax: 82-2-2055-0319 www.topcon.co.kr
TOPCON OPTICAL (H.K.) LIMITED
2/F., Meeco Industrial Bldg., No. 53-55 Au Pui Wan Street, Fo Tan Road,
Shatin, N.T., Hong Kong
Phone: 2690-1328 Fax: 2690-2221 www.topcon.com.hk
TOPCON CORPORATION BEIJING OFFICE
Room No. 962 Poly Plaza Building, 14 Dongzhimen Nandajie,
Dongcheng District, Beijing, 100027, China
Phone: 10-6501-4191~2 Fax: 10-6501-4190
TOPCON CORPORATION BEIRUT OFFICE
P. O. BOX 70-1002 Antelias, BEIRUT-LEBANON.
Phone: 961-4-523525/961-4-523526 Fax: 961-4-521119
TOPCON CORPORATION DUBAI OFFICE
P.O.Box 28595, 102, Al Naily Bldg., 245 Abu Hail Road, Deira,Dubai,UAE
Phone: 971-4-2696511 Fax: 971-4-2695272
RL-H3CS 31336 90030 0210 (2b)