background image

Use the table below to determine operation errors indicated by blink ing lamps on the control panel. 
If corrective action listed does not correct error, please contact your local Topcon dealer.

Operating procedure 

(Setting slope)

Key 

operation

Lamp display 

(Refer to the right illustration)

1

Press Power switch ON. 
You can set the slope after auto-leveling is completed.

Power switch

D uring auto-leveling                      :  Lamp B (Green) blinks.
After auto-leveling is completed.   :  Lamp B (Green) lights.

2

Press either  Slope key once. The laser beam begins 
to move in the direction of the arrow on the key.

After auto-level-

ing is completed.

Slope key

Lamp E (Green) blinks quickly.

3

Press Slope key again to stop the laser beam.

Slope key

Lamp E (Green) lights.

4

Press Slope key to fine adjust the slope. 
Beam movement begins slowly, then  increases 
depending on how long the Slope key is  pressed. 
The blinking speed of the lamp provides a visual indi-
cation of the beam movement speed. 

Slope key

When Slope key is not pressed:  Lamp E (Green) lights.

              Slope key              Lamp E (green)   Beam movement
Press for a shorter time  :   Blinks slowly     :   Moves slowly

         

            

       

 

↓                                      ↓

Press for a  longer  time   :    Blinks quickly   :      Moves quickly

5

Press Power switch OFF to cancel the slope setting.

Power switch

All lamps  are  OFF.

Operating procedure

 (Recalling slope)

Key 

operation

Lamp display 

(Refer to the right illustration.)

1

To recall the previous slope setting (the setting before 
power was OFF), press Power switch ON  while  press-
ing either the right or left Slope key. The  slope  can 
then be adjusted as described in step 

4

 above.  

 When the Power switch is ON  without the Slope key 

pressed, the laser beam  will  return to level.

Slope key

+

Power switch

When Slope key is not pressed:  Lamp E (Green) lights.

              Slope key              Lamp E (green)   Beam movement
Press for a shorter time  :   Blinks slowly     :   Moves slowly

        

            

        

 

↓                                      ↓

Press for a  longer  time   :    Blinks quickly   :      Moves quickly

CHECKS AND ADJUSTMENTS

Checking and adjusting calibration

Checking cone error

Error Code

1

Horizontal calibration of the laser beam can be checked by the user.
[Checking]

1

Set up a tripod approx. 50m (160ft) from a wall. Mount the instrument on the 
tripod, facing the  X1 side toward the  wall.

2

Turn the instrument on and allow auto-leveling to complete.

3

Put the laser sensor in fine detection mode by pressing the On-Grade preci-
sion switch.

4

By using the laser sensor,  mark the center position of  laser beam on the wall. 
(X1)

5

Turn off the  instrument.
Loosen the  tripod  screw, rotate the instrument  180 degrees  and re-secure it 
on the tripod. The X2 side of the instrument faces toward the wall.
When rotating the  instrument,  avoid  changing the height.

6

Turn the  unit  on again and  allow auto-leveling to complete.

7

By using the laser sensor,  mark the center position of  laser beam on the wall. 
(X2)

8

If the difference value of marked two laser beam heights (difference value of 
X1 and X2) are less than 7mm, adjustments are not needed. The difference 
value is greater  than  7mm,  adjust the  instrument  as  described in  right.  *

9

Check the X1 (handle) side as the same way.

X1

X2

[To calibrate the X axis ]

1

Face the X1 side of the instrument  (panel  side) toward a wall,  press  the  Power 
switch while pressing the height  alert  OFF switch.
Then the height alert OFF lamp will light, and manual mode ON lamp will blink. 

2

Press  the height alert  OFF switch to calibrate the X  axis.  The  manual  mode 
ON lamp will light. When auto-leveling finishes, the laser beam will emit.

3

Using the laser  sensor,  mark  the on-grade height  of laser beam  on a wall.

4

Rotate the instrument 180 degrees to face X2 side toward a wall.

5

In the same way as step  3  ,  mark  the on-grade  height of laser beam  on  a wall.

6

By pressing the manual mode ON switch (laser beam moves up), or Power 
switch (laser beam moves down),  adjust the on-grade height  of  the beam until 
it is precisely centered between the marks made in steps  3 and 

7

Press the height alert OFF  switch to  memorize the  new laser beam calibration. 
The height aler t OFF lamp will blink. Power will shut off automatically when the 
calibration memorization is complete.

[To calibrate the Y axis ]

1

Face  the Y1 side of the  instrument  (handle side) toward a  wall, press the 
Power switch while pressing the height alert OFF switch.
Then the height alert OFF lamp will light, and manual mode ON lamp will blink. 

2

Press the Power switch again. The auto leveling lamp will light.

3

Press  the height alert  OFF switch to calibrate the Y  axis.  The  auto  leveling 
lamp will light.

4

Using the laser  sensor,  mark  the on-grade height  of laser beam  on a wall.

5

Rotate the instrument 180 degrees to face Y2 side toward a wall.

6

In the same way as step  4  ,  mark  the on-grade  height of laser beam  on  a wall.

7

By pressing the manual mode ON switch (laser beam moves up), or Power 
switch (laser beam moves down),  adjust the on-grade height  of  the beam until 
it is precisely centered between the marks made in steps  4 and 6.

8

Press the height alert OFF  switch to  memorize the  new laser beam calibration. 
The height aler t OFF lamp will blink. Power will shut off automatically when the 
calibration memorization is complete.

*If the difference value is greater than  60mm (2 3/8 inches), contact your
 Topcon dealer. 

laser sensor

Wall

Approx. 50m

X1 Laser beam

Laser point of X1

Approx. 50m

X1

X2

X1

To discontinue calibration the instrument, press the Power
switch while pressing the height alert OFF switch.

Y1

Y2

[Checking]

1

Set up the laser centered between two walls approximately 40m (131ft) apart. Orient the instrument 
so one  axis, either  X or Y, is facing the walls.

2

Locate and  mark the position of the rotating laser beam on both walls using the laser sensor.

3

Turn off the instrument and move the instrument closer to wall A (1m to  2m /3 ft to 6 ft).
Do not change the axis orientation of  the instrument. Turn the instrument on.

4

Again locate and mark the position  of  the  rotating laser beam on both walls using the laser sensor.

5

Measure the  distance between  the  first and second marks on each wall. 
If the difference between each set of marks is less than 4mm (5/32 of an inch), no error exists.

Perfor m the following check after com pleting horizontal calibration procedure.

Cone error

Datum position

2

3

Lamp Indication

Error Code

Corrective Action

Lamp B, C and D blink in turn

Auto-leveling range 
error

Correct tilt of the instrument until it less 
than 3 degrees.

Lamp A lights

Batter y power error

Replace all 4 batteries with new ones at 
the sam e time. 

Lamp B, C and D blink simulta-
neously

Height alert error

Turn power off, rough level the instrument, 
then turn power on again. Check height of 
laser beam as it may have changed.

Lamp D blinks quickly

Calibration error

Repeat calibration procedure. If error re-
peats contact your local Topcon dealer.

Lamp E(Red) lights
Lamp B, C and D blink in turn

Slope setting range 
error

Push the slope key of the opposite side,  
and align slope.

Lamp A, B, C and D blink si-
multaneously

Internal error

Turn power off, then on again. If error re-
peats contact your local Topcon dealer.

A

B

D

C

LS-70B
Beam detection window

: 50mm (2.0 in)

Beam detection precision

: High precision      : ±1mm(±0.04 in)
: Normal precision  : ±2mm(±0.08 in)

Beam detection 
                    indication

: Liquid crystal and buzzer

Power source

: DC 9V alkaline (dry) battery

Operating time

: Approx. 80 hours at +20°C (+68°F)

(Using alkaline manganese dry batteries)

Auto shut-off delay

: Approx.  30 minutes without beam detection.

Operating temperature

: -20°C~+50°C (-4°F~+122°F)

Dimensions

: 165(L)x78(W)x26(H)mm
 (6.5x3.0x1.0 

in)

Weight

: 0.25 kg [0.55 lbs] (With dry batteries)

SPECIFICATIONS

RL-H3CS
Accuracy

: ±3.6mm/50m (±15 ”)

Automatic correction range + Setting slope range : ±5°
Beam detecting range

: Approx. 2m~300m (6ft~980ft) diameter

Rotational speeds

: 600r.p.m

Laser source

: Laser diode (Visible, Red)

Laser power output

: 0.8mW (Max.)

Laser class

: Class 2 laser product

Power supply

: Four C size alkaline 

         manganese dry batteries

Operating time

: Approx. 60 hours at +20°C (+68°F)

Protection against
          water and dust

: IP56 

                                            

 (Based on the standard IEC 60529)

Operating temperature

: -20°C~+50°C (-4°F~+122°F)

Dimensions

: 167(L)x182(W)x193(H)mm

(6.5x7.1x7.6 in)

Weight

: 1.9kg[4.1lbs] (With dry batteries)

X2 Laser beam

Wall A

Wall B

Wall A

Approx. 40m

*If the difference value is greater than 4mm(5/32 inch), contact your Topcon dealer. 

When calibration is memorizing, if the height alert lamp
continues to blink quickly and power does not shut-off auto-
m atically, please contact your local Topcon dealer.

HOW TO  OPERATE

1

Set the instrument to the tripod or smooth surface.

2

Make sure instrument is roughly level.

3

Press power switch (ON).

4

Press power switch on laser sensor (ON).

5

Select  the precision mode  by pressing the 
On-Grade precision switch.

6

Locate the on-grade position “---” by moving 
the laser sensor up and down.

7

Mark the position of On-Grade index. 
(Top of the Laser Sensor is 40mm [1 9/16"] from 
index for offset marking.)

LS-70B Indicator

High precision mode

Normal precision mode

Battery remaining display

Below grade indicator
Move the sensor up.
Audio signal:Lower pitch, slower frequency

Above grade indicator
Move the sensor down.
Audio signal:High pitch, frequent beep

When using the Laser 
Sensor with other 
select Topcon  lasers, 
these symbols alert 
user if laser batteries 
are low or if laser has 
been disturbed. 
These symbols are 
not active when used 
with RL-H3CS.

Aligning Direction of  Slope

When using the laser to set the slope, the laser 
must be properly aligned so the slope axis of  the 
laser beam  is parallel  to the desired  direction  of 
slope.
The sight on top of the instrument is calibrated to 
the slope axis of the laser beam. Follow the 
steps below to align the laser to the desired 
direction of slope:

1

Establish a target line parallel to  desired 
direction of slope.

2

Set  up  the laser over  this line (drop  a plumb 
bob from  the tripod mounting  screw).

3

Rough align the instrument  to the direction of 
slope.  Make sure it  is properly oriented for the 
slope to be set.

4

Using the sight, position the instrument so the 
sight is  centered on the target. (see illustra-
tion at  right)   

On-Grade position
Audio signal:Continuous beep sound

[Setting slope]

Manual mode can be activated 
while the slope is set. 
For information about  Manual 
mode ON/OFF, refer to "NOMEN-
CLATURE AND  FUNCTIONS".

Check the beam often during 
slope use for slope accuracy. 
Check instrument calibration peri-
odically (see belo w).

E

Target

Wall B

TOPCON CORPORATION

75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan  
Phone: 3-3558-2520  Fax: 3-3960-4214   www.topcon.co.jp

TOPCON POSITIONING SYSTEMS, INC.

5758 West Las Positas Blvd., Pleasanton, CA 94588, U.S.A.
Phone: 925-460-1300 Fax: 925-460-1315 www.topcon.com
TOPCON CALIFORNIA
3380 Industrial Blvd, Suite 105, West Sacramento, CA 95691, U.S.A.
Phone: 916-374-8575 Fax: 916-374-8329
TOPCON MIDWEST
891 Busse Road, Elk Grove Village, IL 60007, U.S.A.
Phone: 847-734-1700 Fax: 847-734-1712

TOPCON EUROPE B.V.

Essebaan 11, 2908 LJ Capelle a/d IJssel, The Netherlands.
Phone: 010-4585077 Fax: 010-4585045 www.topconeurope.com

TOPCON BELGIUM

Preenakker 8, 1785 Merchtem, Belgium
Phone: 052-37.45.48 Fax: 052-37.45.79 

TOPCON DEUTSCHLAND G.m.b.H.

Weidkamp 180, 45356 Essen, GERMANY
Phone: 0201-8619-100 Fax: 0201-8619-111  [email protected]
www.topcon.de

TOPCON S.A.R.L. 

89, Rue de Paris, 92585 Clichy, Cedex, France.
Phone: 33-1-41069490  Fax: 33-1-47390251  [email protected] 

TOPCON ESPAÑA S.A.

HEAD OFFICE
Frederic Mompou 5, ED. Euro 3, 08960, Sant Just Desvern Barcelona, Spain.
Phone: 93-473-4057 Fax: 93-473-3932  www.topconesp.com
MADRID OFFICE
Avenida Burgos, 16E, 1∞28036, Madrid, Spain.
Phone: 91-302-4129 Fax: 91-383-3890

TOPCON SCANDINAVIA A. B. 

Neongatan 2 S-43151 Mölndal, SWEDEN
Phone: 031-7109200 Fax: 031-7109249

TOPCON (GREATBRITAIN) LTD.

HEAD OFFICE
Topcon House Kennet Side, Bone Lane, Newbury, Berkshire RG14 5PX U.K.
Phone: 44-1635-551120 Fax: 44-1635-551170
[email protected]   [email protected]

TOPCON SOUTH ASIA PTE. LTD.

Blk 192 Pandan Loop, Pantech Industrial Complex, #07-01, Singapore 128381
Phone: 62780222 Fax: 62733540  www.topcon.com.sg

TOPCON AUSTRALIA PTY. LTD.

408 Victoria Road, Gladesville, NSW 2111, Australia
Phone: 02-9817-4666 Fax: 02-9817-4654  www.topcon.com.au

TOPCON INSTRUMENTS (THAILAND) CO., LTD.

77/162 Sinn Sathorn Tower, 37th Fl.,
Krungdhonburi Rd., Klongtonsai, Klongsarn, Bangkok 10600 Thailand.
Phone: 662-440-1152~7  Fax: 662-440-1158

TOPCON INSTRUMENTS (MALAYSIA) SDN. BHD.

Excella Business Park Block C, Ground & 1st Floor,   Jalan Ampang Putra, 
Taman Ampang Hilir, 55100 Kuala Lumpur, MALAYSIA  
Phone: 03-42701068  Fax: 03-42704508

TOPCON KOREA CORPORATION

2F Yooseoung Bldg., 1595-3, Seocho-Dong, Seocho-gu, Seoul, 137-876, Korea.
Phone: 82-2-2055-0321 Fax: 82-2-2055-0319  www.topcon.co.kr

TOPCON OPTICAL (H.K.) LIMITED

2/F., Meeco Industrial Bldg., No. 53-55 Au Pui Wan Street, Fo Tan Road, 
Shatin, N.T., Hong Kong
Phone: 2690-1328  Fax: 2690-2221  www.topcon.com.hk

TOPCON CORPORATION BEIJING OFFICE

Room No. 962 Poly Plaza Building, 14 Dongzhimen Nandajie,
Dongcheng District, Beijing, 100027, China
Phone: 10-6501-4191~2  Fax: 10-6501-4190

TOPCON CORPORATION BEIRUT OFFICE

P. O. BOX 70-1002 Antelias, BEIRUT-LEBANON. 
Phone: 961-4-523525/961-4-523526  Fax: 961-4-521119 

TOPCON CORPORATION DUBAI OFFICE

P.O.Box 28595, 102, Al Naily Bldg., 245 Abu Hail Road, Deira,Dubai,UAE
Phone: 971-4-2696511  Fax: 971-4-2695272 

RL-H3CS          31336 90030     0210 (2b)  

Reviews: