TeamPoS 3000 XL and XL
2
Installation
D900000145
Issue 3
5-33
5.11.4
Combo Board with COM Board (XL Motherboard only)
(XL
2
Motherboard does not support the COM board)
Caution:
Ports designated as Port C on the backplane (24V PUSB) and Port 3
on the Combo board (24V RS232) do not meet UL limited power source (LPS)
requirements. These ports are limited to only allowing 24V Retail POS RS232
or powered USB peripherals that do not exceed a rated current of 4 Amps and
are provided with a Fire Enclosure, Rated Min. V-1 or Metal. Peripherals
intended to be connected via - Jacketed Cable for external use rated 30 V, max
3.05m long, marked VW-1 or FT-1.
Note
: When Combo Board is installed, only one 24V port should be used for 24V printer. Port 3
and Port C cannot provide 24V power to 2 printers simultaneously.
1.
Remove the back panel. (See Section 5.1.2).
2.
Disconnect the AC power cord from the controller.
3.
Remove the front panel (See Section 5.1.1). The yellow LED should be off (See Section
1.2).
4.
Unseat the motherboard (See Section 5.2).
5.
Remove the backplane assembly (See Section 5.9).
Summary of Contents for TeamPoS 3000 XL
Page 1: ...Installation Maintenance Manual TeamPoS 3000 XL and XL2 ...
Page 2: ...TeamPoS 3000 Installation and Maintenance Manual ...
Page 17: ...TeamPoS 3000 XL and XL2 Overview D900000145 Issue 3 1 7 This Page Intentionally Left Blank ...
Page 38: ...TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3 17 This page intentionally left blank ...
Page 98: ...TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5 52 ...
Page 105: ...TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5 59 DV15 ready for VESA mounting ...