TeamPoS 3000 XL and XL
2
Site Preparation
D900000145
Issue 3
4-6
4.8
Installation with Other Equipment
In most cases, dedicated AC mains circuits are not required for the TeamPoS
3000XL and XL
2
terminals. In rare instances, other electrical equipment sharing
power with the terminal may cause adverse effects on the terminal. When this
occurs, electrical isolation may be required and is the responsibility of the
customer or installing contractor.
Terminals at 100-240 volts
The table below details the power requirements for the TeamPoS series control
unit. Provide 100-240 volts AC, 50/60 Hz, single phase, with the following
amperage requirements:
Property
Value or Description
Grounding
The terminals are Class 1 equipment and must be
supplied via a socket-outlet which has a protective
ground contact connected to the protective ground of the
terminal.
Power system
The terminals are designed for use on a power system
with a grounded neutral, i.e., a TN or TT power system.
The terminals must not be directly connected to a power
system with impedance grounded neutral, i.e., an IT
power system.
Rated voltage and frequency
100 - 240 volts, 50/60 Hz
Rated current
1.8 A / 3.6 A
Operational freque ncy limits
47 – 63 Hz
Earth leakage current
< 1.0 mA
Power dissipation
250 watts
Maximum HRC fuse rating for
external short-circuit protection
10 A / 20 A
Main power cord:
Length
Diameter
Minimum bend radius
3.00 m (9.80 ft.)
8.0 mm (0.30 in.)
10.0 mm (0.40 in.)
Summary of Contents for TeamPoS 3000 XL
Page 1: ...Installation Maintenance Manual TeamPoS 3000 XL and XL2 ...
Page 2: ...TeamPoS 3000 Installation and Maintenance Manual ...
Page 17: ...TeamPoS 3000 XL and XL2 Overview D900000145 Issue 3 1 7 This Page Intentionally Left Blank ...
Page 38: ...TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3 17 This page intentionally left blank ...
Page 98: ...TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5 52 ...
Page 105: ...TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5 59 DV15 ready for VESA mounting ...