7
3. INSTALLING BRACKETS
Install the brackets with nuts, washers and spring
washers. (Fig. 18)
When drain hose is arranged backward. Secure the
drain hose with the VT wire. (Fig. 22)
Fig. 18
Spring washer
Special nut
Bracket
Bracket (Left)
Bracket (Right)
Fig. 21
Remove the hole cover.
Drain hose
Arrange the drain hose
lower than this portion.
OK
NO
Fig. 22
Piping hole
Base (Bottom)
VT wire
hole
Intake
grille
VT wire
4. INSTALLING INDOOR UNIT
Reset the hex bolts as shown in Fig.19.
5. INSTALL THE DRAIN HOSE
Select whether the drain hose will be connected to the
left or right side. (Fig. 6)
Insert the drain hose into the drain pan, then secure
the drain hose with a nylon fastener. (Fig. 9)
Wrap the insulation (drain hose) around the drain
hose connection. (Fig. 10)
Be sure to arrange the drain hose so that it is leveled
lower than the drain hose connecting port to the
indoor unit. (Fig. 21)
Apply the indoor unit to the brackets.(Fig. 20)
Now, securely tighten the hex bolts in both sides.
Fig. 19
Indoor unit
Hex bolt
5/16” to 1/2”
(8 to 1 3mm)
Fig. 20
Bolt
Bracket
Indoor unit
Cut the grille
Drain hose
Pass the drain hose
through here.
3. OUTDOOR UNIT INSTALLATION
• When the outdoor unit will be exposed to strong
wind, fasten it with bolts at the places indicated by
the arrows. (Fig. 23)
Fig. 23
Bottom