5-26
SPARC Enterprise T2000 Server Service Manual • April 2007
FIGURE 5-16
Securing the Motherboard Assembly to the Chassis
8. Secure the motherboard assembly to the chassis with the remaining screws and an
insulating washer (
).
Do not fully tighten any screws until all of the screws are loosely installed.
One insulating washer is required in the position shown in
. A washer is
supplied with the replacement FRU. Install the washer in this position even if the
original motherboard did not have a washer.
9. Tighten the two bus bar screws to secure the bus bar to the motherboard
assembly.
10. Reinstall the system controller card in the motherboard assembly.
See
Section 5.2.6, “Replacing the System Controller Card” on page 5-18
11. Reinstall all DIMMs in the motherboard assembly in the slots from which they
were removed.
See
Section 5.2.4, “Replacing DIMMs” on page 5-14
12. Reinstall any PCI option cards that were removed.
See
Section 5.2.2, “Replacing PCI Cards” on page 5-11
Bus bar
screws
Install these two screws first
to properly align the board
Insulating washer
Summary of Contents for SPARC Enterprise T2000
Page 1: ......
Page 2: ......
Page 6: ......
Page 16: ...xiv SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 18: ...xvi SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 27: ...Preface xxv Reader s Comment Form ...
Page 43: ...Chapter 3 Server Diagnostics 3 3 FIGURE 3 1 Diagnostic Flow Chart flowchart ...
Page 106: ...4 12 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 152: ...5 46 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 173: ......
Page 174: ......