5-14
SPARC Enterprise T2000 Server Service Manual • April 2007
3. Note the DIMM locations so you can install the replacement DIMMs in the same
sockets.
4. Push down on the ejector levers on each side of the DIMM connector until the
DIMM is released.
5. Grasp the top corners of the faulty DIMM and remove it from the system.
6. Place DIMMs on an antistatic mat.
5.2.4
Replacing DIMMs
1. Unpackage the replacement DIMMs and place them on an antistatic mat.
2. Ensure that the connector ejector tabs are in the open position.
3. Line up the replacement DIMM with the connector.
Align the DIMM notch with the key in the connector. This action ensures that the
DIMM is oriented correctly.
4. Push the DIMM into the connector until the ejector tabs lock the DIMM in place.
5. Perform the procedures described in
Section 5.3, “Common Procedures for
CH1/R1/D0
J1301
CH1/R0/D0
J1101
CH2/R1/D1
J1901
CH2/R0/D1
J1701
CH2/R1/D0
J1801
CH2/R0/D0
J1601
CH3/R1/D1
J2401
CH3/R0/D1
J2201
CH3/R1/D0
J2301
CH3/R0/D0
J2101
* DIMM names in messages are displayed with the full name
such as
MB/CMP0/CH1/R1/D1
. This table omits the preced-
ing
MB/CMP0
for clarity.
TABLE 5-1
DIMM Names and Socket Numbers
(Continued)
DIMM Name Used in Messages
*
Socket No.
Summary of Contents for SPARC Enterprise T2000
Page 1: ......
Page 2: ......
Page 6: ......
Page 16: ...xiv SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 18: ...xvi SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 27: ...Preface xxv Reader s Comment Form ...
Page 43: ...Chapter 3 Server Diagnostics 3 3 FIGURE 3 1 Diagnostic Flow Chart flowchart ...
Page 106: ...4 12 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 152: ...5 46 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 173: ......
Page 174: ......