Chapter 5
Replacing Cold-Swappable FRUs
5-11
FIGURE 5-7
PCI Card and Hold-Down Bracket
6. Carefully pull the card out of the socket.
7. Place the card on an antistatic mat.
8. Rotate the hold-down bracket so that it does not protrude into the chassis.
5.2.2
Replacing PCI Cards
1. Unpackage the replacement PCI-Express or PCI-X card and place it on an antistatic
mat.
2. Locate the proper socket for the card you are replacing.
3. Rotate the PCI hold-down bracket 90 degrees so you can install the card.
4. Insert the card into the socket.
5. Rotate the PCI hold-down bracket 90 degrees to lock the card in place.
6. Perform the procedures described in
Section 5.3, “Common Procedures for
PCI hold-down bracket