170
ServerView
Event
Manager
MIB integration
The tool starts up and the following window is displayed:
Figure 15: “MIB Manager” tool
To integrate private MIBs, proceed as follows:
Ê
Select the relevant directory using the
Browse...
button.
Ê
Select the MIB and then click the
Upload
button. The tool then checks the
MIB for correct syntax. In the next window a message shows the status.
Ê
Click the
Save parsed MIB
button to integrate the MIB.
Ê
In the next window, select
Close
to close the tool.
I
After a third-party MIB has been integrated, the Java plug-in cache must
be cleared. Under Windows the
ServerView Services
must be restarted.
Under Linux it is sufficient just to restart the
SVForwardServer
with:
/etc/init.d/sv_fwdserver restart
.
Viewing integrated MIB files
You can find out which MIBs are integrated in the Event Manager via the
Alarm
Configuration
window (in the
MIB
column of the
Alarm Rules - Assign Alarms
dialog
box) or via the Event Manager online help.
For a more detailed explanation of how to access the MIB overview window via
help, see
section "Displaying trap information" on page 81
.