l
Idler roller
l
Glass
l
Pick roller assembly
l
White backing strip
1. Unplug the power connection cable (power cable or USB bus power cable) from the power
supply source (AC outlet or computer).
2. Pull the ADF release tab to open the ADF top section.
ADF Paper Chute (Cover)
ADF Release Tab
ADF Top Section
3. Clean the following locations with a cloth moistened with Cleaner F1.
Pad Assy
Pick Spring (Metal Part)
*Gray Part
Pick Roller Assembly
White Backing Strip (x 2)
(including the one on the ADF
top section)
Glass (x 2)
(including the one on the ADF
top section)
Idler Roller
(x 4)
l
Idler roller (× 4, located on the ADF top section)
Gently wipe the dirt and dust off the rollers as you rotate them manually. Be careful not
to damage the surface of the rollers. Make sure that they are cleaned properly because
residue on the rollers will affect the feeding performance.
l
Pad assy (× 1, located on the ADF top section)
Wipe the rubber surface of the pad downward to remove any dirt and dust. Be careful
not to accidentally get your hand or a cloth on the pick spring (metal part).
l
Pick roller assembly (× 1)
Cleaning the Inside of the ScanSnap
98