7. Various control
7-1. Auto restart
When the power was interrupted by a power failure etc. during operation, the operation contents at
that time are memorized and when the power is recovered, operation is automatically started with
the memorized operation contents.
Operation contents memorized when the power is interrupted
Operation mode
Setting temperature
Fan mode setting
Timer mode and set time (set by wireless remote controller)
Airflow direction setting
Swing
ECONOMY operation
Remote control setting
WLAN LED setting
7-2. MANUAL AUTO operation
When the wireless remote controller is lost or battery power dissipated, this function will work without
the remote controller.
When MANUAL AUTO button is pressed more than 3 seconds and less than 10 seconds, MANUAL
AUTO operation starts as shown in the table below. To stop operation, press the MANUAL AUTO
button for 3 seconds.
Operation mode
Auto changeover
Fan mode
AUTO
Timer mode
Continuous (no timer setting available)
Setting temperature
24°C
Vertical airflow direction louver setting
Standard
SWING
Off
ECONOMY
Off
Human sensor
Off
7-1. Auto restart
- (04-23) -
7. Various control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Summary of Contents for ROG07KPCA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2021 12 16 SR_CH01_AS059EJ_01 ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2021 12 16 SR_CH02_AS059EJ_01 ...
Page 31: ...3 TROUBLESHOOTING 2021 12 16 SR_CH03_AS059EJ_01 ...
Page 34: ......
Page 91: ...4 CONTROL AND FUNCTIONS 2021 12 16 SR_CH04_AS059EJ_01 ...
Page 123: ...5 FILED WORKING 2021 12 16 SR_CH05_AS059EJ_01 ...