1.5
Technical data
Electrical data
Compliance with regulations and standards
Rated voltage range
100 V - 240 V
Frequency
50 Hz - 60 Hz
Rated current with basic configu-
ration
100 V - 240 V / 1.9 A - 0.8 A
Max. rated current
100 V - 240 V / 6 A - 3 A
Effective power
64 W - 232 W
Apparent power
86 VA - 263 VA
Heat dissipation
230 kJ/h - 835 kJ/h (218 btu/h - 792 btu/h)
Main power fuse
16 A
Protection class
I
Product safety and
ergonomics
IEC 60950-1 / EN 60950-1, UL/CSA 60950-1,
CNS 14336 / GB 4943 / EN 50371
Electromagnetic
compatibility
FCC class A
CNS 13438 class A; VCCI class A
AS/NZS CISPR 22 class A / GB 9254 class A
GB 17625
Interference emissions EN 55022 class A
Harmonic current
EN 61000-3-2
Flicker
EN 61000-3-3
ETSI EN 300 386 V1.3.1
Interference immunity
EN 55024, EN 300386
CE marking
to EU directives
Low Voltage Directive 2006/95/EC
(product safety)
Electromagnetic compatibility 2004/108/EC
Environmental conditions
ETSI 300 019-2-3 Class 3.1 (T3.1)
Noise emission
ETSI 300 753 Class 3.1