TX1320 M4
Operating Manual
89
Troubleshooting and tips
Temperature warning
A temperature warning is output to the hardware event log and OS event log, or
ServerView issues a notification of a temperature warning such as by a popup
message.
This warning is issued by ServerView when the ambient temperature exceeds
the upper limit of the temperature boundaries. The upper limit is 35°C for
standard server and 40°C or 45°C with Advanced Thermal Design.
Added drive reported as defective
Cause
Troubleshooting
The ambient
temperature exceeds
the upper limit of the
temperature
boundaries
Ê
Although continued use within the temperature
boundaries poses no problems within itself,
reconsider the surrounding environment
conditions if this log is output or if ServerView
issues this notification.
Cause
Troubleshooting
RAID controller is not
configured for this
drive
The drive was probably installed when the system
was switched off.
Ê
Reconfigure the RAID controller for the drive
using the corresponding utility. Information is
provided in the documentation for the RAID
controller.
or
Ê
Remove and reinstall the drive while the system is
switched on.
If the HDD/SSD continues to be shown as
defective, then replace it (see the "FUJITSU
Server PRIMERGY TX1320 M4 Server Upgrade
and Maintenance Manual").
Summary of Contents for PRIMERGY TX1320 M4
Page 6: ...Operating Manual TX1320 M4 ...
Page 10: ...Operating Manual TX1320 M4 Content ...
Page 12: ...12 Operating Manual TX1320 M4 Introduction ...
Page 16: ...16 Operating Manual TX1320 M4 Before you start ...
Page 40: ...40 Operating Manual TX1320 M4 Product description ...
Page 54: ...54 Operating Manual TX1320 M4 Important information ...
Page 84: ...84 Operating Manual TX1320 M4 Operation ...
Page 92: ...92 Operating Manual TX1320 M4 Troubleshooting and tips ...
Page 102: ...102 Operating Manual TX1320 M4 Warranty and service ...