TX100 S2
Service Supplement
33
Replacement routines
4.1.4
Removing or installing the air duct
4.1.4.1
Removing the air duct
The following replacement routines require removing the air duct:
–
Replacing the front fan module (system fan 1)
–
Replacing the front panel cable
–
Removing the processor heat sink
–
Replacing the processor
–
Replacing the system board
I
This procedure is best performed with the server in a horizontal position.
Ê
Shut down the server and disconnect the AC power cord from the system.
Ê
Remove the side cover as described in section
4.1.1.1 on page 23
.
Ê
Open the HDD cage as described in section
4.1.2.1 on page 25
.
Part number: C26361-K1007-C871-*-3298