52
U41662-J-Z156-1-76
Operating and Indicator Elements
Commissioning and Operation
Global Error indicator (green/orange)
Does not light when power is switched OFF or a POST error has
occurred.
Lights green when the system is ok. The power is ON, no service
incident or event has occurred.
Flashes green when a processor or a memory component has
failed.
Lights orange when a critical event has occurred. Users can
check the
BIOS Setup
or the system and event log via
ServerView
for event details.
Flashes orange when a non-critical (prefailure) event has been
recognized. Users can check the system and event log via
ServerView
for event details.
If the event is still acute after a power failure, the indicator is
activated after the restart.
Power-on indicator (green)
Lights when the server is switched ON.
Flashes when the server is switched ON and is in sleep mode
(ACPI status S1)
Does not light when the server is switched OFF.
ID
ID indicator (blue)
Lights blue when the system has been selected by pressing the
ID button. To deactivate, press the button again.
The ID indicators (blue) on the front and on the rear of the server
light up synchronously when the ID button is pressed.
The ID indicator can also be activated via
ServerView
and its status
reported to
ServerView
.
!