192
Chapter 7 Installing Internal Options
5
Press the [F10] key.
A message confirming whether to save the BIOS setting change is displayed.
6
Select [Yes] and press the [Enter] key.
After the system restarts, the memory mirror configuration becomes effective.
7.4.3 How to Install or Remove Memory Modules
1
Turn off the power and remove the top cover.
"7.2 Installing/Removing the Top Cover" (pg.182)
2
Touch a metal part of the server to discharge static electricity.
3
Remove the fan duct.
Lift and remove the fan duct.
4
Pull the levers on both sides of the slot where the memory module is to be
installed outwards.
Use the same procedure when exchanging memory modules.
• After the server shutdown, memory modules remain very hot. Wait for a
sufficient period of time after the server shutdown before removing memory
modules. Failure to do so may cause burns.
• If a memory module is installed and you pull the hook strongly outwards, the
memory module pops up. Doing so may cause a device failure.
Fan duct
Lever