17.4
Minimum startup configuration
Field Replaceable Units
(FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
Notes
System board
no TPM or expansion cards installed
1 CPU with CPU heat
sink
installed in CPU slot CPU 1
1 memory module
installed in DIMM slot 1A
Common Operation
Panel (COP)
1 PSU
installed in PSU bay PSU 1
Table 5: Minimum startup configuration - components
Cable
Notes
Front panel cable
Power cable
Table 6: Minimum startup configuration - cables
▶
"Shutting down the server" on page 52
▶
"Disconnecting the power cord" on page 53
▶
Take the system down to its minimum startup configuration.
▶
"Connecting the power cord" on page 65
.
▶
Connect a display to the server.
▶
Switch on the server, see
"Switching on the server" on page 69
.
Appendix A
568
Upgrade and Maintenance Manual
RX2540 M6
Summary of Contents for PRIMERGY RX2540 M6
Page 8: ...Upgrade and Maintenance Manual RX2540 M6 ...
Page 34: ...Before you start 34 Upgrade and Maintenance Manual RX2540 M6 ...
Page 86: ...Basic hardware procedures 86 Upgrade and Maintenance Manual RX2540 M6 ...
Page 120: ...Basic software procedures 120 Upgrade and Maintenance Manual RX2540 M6 ...
Page 232: ...Fans 232 Upgrade and Maintenance Manual RX2540 M6 ...
Page 328: ...Expansion cards and backup units 328 Upgrade and Maintenance Manual RX2540 M6 ...
Page 366: ...Processor CPU 366 Upgrade and Maintenance Manual RX2540 M6 ...
Page 462: ...Front panel 462 Upgrade and Maintenance Manual RX2540 M6 ...
Page 570: ...Appendix A 570 Upgrade and Maintenance Manual RX2540 M6 ...
Page 672: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...