4.7
Connecting the power cord
4.7.1
Connecting the power cord (AC PSU)
CAUTION
The AC PSU adjusts automatically to any mains voltage in the range
from 100 V - 240 V (AC PSU Platinum) or 200 V - 240 V (AC PSU
Titanium).
▶
You may only operate the server if its rated voltage range
corresponds to the local mains voltage.
▶
Connect the power cord to the PSU.
▶
If applicable, connect the main plug to an power outlet of the rack socket
strip.
To provide true phase redundancy, the second PSU should be
connected to a different AC power source from the other PSU. If one
AC power source should fail, the server will still continue to run.
▶
Ensure that the status indicator on the PSU is lit green, see
.
You can secure the power cord with a cable clamp to ensure that the
power cord cannot be disconnected from the server by mistake.
Basic hardware procedures
RX2540 M6
Upgrade and Maintenance Manual
65
Summary of Contents for PRIMERGY RX2540 M6
Page 8: ...Upgrade and Maintenance Manual RX2540 M6 ...
Page 34: ...Before you start 34 Upgrade and Maintenance Manual RX2540 M6 ...
Page 86: ...Basic hardware procedures 86 Upgrade and Maintenance Manual RX2540 M6 ...
Page 120: ...Basic software procedures 120 Upgrade and Maintenance Manual RX2540 M6 ...
Page 232: ...Fans 232 Upgrade and Maintenance Manual RX2540 M6 ...
Page 328: ...Expansion cards and backup units 328 Upgrade and Maintenance Manual RX2540 M6 ...
Page 366: ...Processor CPU 366 Upgrade and Maintenance Manual RX2540 M6 ...
Page 462: ...Front panel 462 Upgrade and Maintenance Manual RX2540 M6 ...
Page 570: ...Appendix A 570 Upgrade and Maintenance Manual RX2540 M6 ...
Page 672: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...