RX2540 M5
Operating Manual
33
Product description
2
[CSS]
CSS
indicator
off
No critical event detected (CSS
component).
orange
on
Prefailure event detected (CSS
component).
For HDDs/SSDs, see also
"HDD/SSD prefailure detection" on
page 35
.
flashing
orange
CSS component failure detected.
3
Global
Error
indicator,
see also
"iRMC-
related
status
signals" on
page 35
off
No critical event detected (non CSS
component).
orange
on
Prefailure event detected (non CSS
component).
flashing
orange
Non CSS component failure
detected.
Possible causes:
– System is out of the specified
temperature range
– Defective sensor
– CPU error
– Error detected by server
management software
4
HDD/SSD
activity
indicator
flashing
green
Data access in progress.
5
Power-on
indicator
off
The server is switched off.
green on
– The server has been switched on
but Power Cycle Delay settings
delay it from turning on for a
specified time.
– The server is switched on and
operating normally.
flashing
green
slowly
The BMC firmware is starting up after
the server has been connected to the
mains.
Pos. Label
Indicator
Status
Description
!
Summary of Contents for PRIMERGY RX2540 M5
Page 1: ...Operating Manual English FUJITSU Server PRIMERGY RX2540 M5 Operating Manual March 2019 ...
Page 6: ...Operating Manual RX2540 M5 ...
Page 10: ...Operating Manual RX2540 M5 Content ...
Page 12: ...12 Operating Manual RX2540 M5 Introduction ...
Page 16: ...16 Operating Manual RX2540 M5 Before you start ...
Page 44: ...44 Operating Manual RX2540 M5 Product description ...
Page 58: ...58 Operating Manual RX2540 M5 Important information ...
Page 92: ...92 Operating Manual RX2540 M5 Operation ...
Page 100: ...100 Operating Manual RX2540 M5 Troubleshooting and tips ...
Page 110: ...110 Operating Manual RX2540 M5 Technical data ...
Page 112: ...112 Operating Manual RX2540 M5 Warranty and service ...