![Fujitsu PRIMERGY GX2460 M1 Upgrade And Maintenance Manual Download Page 90](http://html.mh-extra.com/html/fujitsu/primergy-gx2460-m1/primergy-gx2460-m1_upgrade-and-maintenance-manual_121058090.webp)
90
Upgrade and Maintenance Manual
GX2460 M1
Hard disk drive (HDD) and solid state drive (SSD)
7.3.3.2
Removing a 2.5-inch HDD/SSD module
Figure 40: Opening the locking lever
Ê
Press the locking lever to open the HDD/SSD module.
Figure 41: Removing the HDD/SSD dummy module
Ê
Pull the HDD/SSD module out a few centimeters.
Ê
Wait about 30 seconds to allow the HDD to spin down.
I
This is not necessary when removing an SSD.
I
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
Ê
Pull the HDD/SSD module completely out of its bay.
7.3.3.3
Concluding steps
Ê
No steps needed.
Summary of Contents for PRIMERGY GX2460 M1
Page 16: ...16 Upgrade and Maintenance Manual GX2460 M1 Contents ...
Page 26: ...26 Upgrade and Maintenance Manual GX2460 M1 Before you start ...
Page 56: ...56 Upgrade and Maintenance Manual GX2460 M1 Basic hardware procedures ...
Page 78: ...78 Upgrade and Maintenance Manual GX2460 M1 Power supply unit PSU ...
Page 96: ...96 Upgrade and Maintenance Manual GX2460 M1 Hard disk drive HDD and solid state drive SSD ...
Page 108: ...108 Upgrade and Maintenance Manual GX2460 M1 Fans ...
Page 158: ...158 Upgrade and Maintenance Manual GX2460 M1 Expansion cards and riser modules ...
Page 242: ...242 Upgrade and Maintenance Manual GX2460 M1 Appendix A ...
Page 244: ...244 Upgrade and Maintenance Manual GX2460 M1 Appendix B ...
Page 250: ...RAID Card RAID Card HDD Back Plane 411T61300070 SAS MLC1 SAS MLC2 SATA 0 3 SATA 4 7 C17 C17 ...