GX2460 M1
Upgrade and Maintenance Manual
59
Basic software procedures
Option ROM can be enabled permanently (e.g. in case of a boot controller that
may require frequent setup) or temporarily for one-time configuration. When
permanently enabling a controllers’s Option ROM, keep in mind that only two
Option ROMs can be activated in the BIOS at a time.
Ê
Enter the BIOS.
Ê
From the
Advanced
menu select
Option ROM Configuration
.
Ê
Identify the desired PCI slot and set its
Launch Slot # OpROM
setting to
Enabled.
Ê
Save your changes and exit the BIOS.
I
Up to two Option ROMs can be activated in the BIOS at a time.
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
When the enabled expansion card is initialized during the POST phase of the
boot sequence, a key combination is displayed temporarily to enter the firmware
of the expansion card.
Ê
Press the displayed key combination.
Ê
Modify the expansion card firmware options as desired.
Ê
Save your changes and exit the firmware.
I
The option ROM of the expansion card can now be disabled in the BIOS.
Exception: If the expansion card controls a permanent boot device, the
Option ROM of the expansion card has to remain enabled.
5.2.3
Verifying the system time settings
After the system board has been replaced, the system time is set automatically.
By default, the RTC (Real Time Clock) time standard is set as the local time.
If a Linux OS is used and the hardware clock has been configured as UTC
(Universal Time, Coordinated) in the operating system, the BMC local time may
not be mapped correctly.
Ê
After replacing the system board, ask the system administrator whether the
RTC or UTC time standard is to be used as system time.
I
If the system time (RTC) is set to UTC, the SEL (System Event Log)
time stamps may differ from the local time.
Summary of Contents for PRIMERGY GX2460 M1
Page 16: ...16 Upgrade and Maintenance Manual GX2460 M1 Contents ...
Page 26: ...26 Upgrade and Maintenance Manual GX2460 M1 Before you start ...
Page 56: ...56 Upgrade and Maintenance Manual GX2460 M1 Basic hardware procedures ...
Page 78: ...78 Upgrade and Maintenance Manual GX2460 M1 Power supply unit PSU ...
Page 96: ...96 Upgrade and Maintenance Manual GX2460 M1 Hard disk drive HDD and solid state drive SSD ...
Page 108: ...108 Upgrade and Maintenance Manual GX2460 M1 Fans ...
Page 158: ...158 Upgrade and Maintenance Manual GX2460 M1 Expansion cards and riser modules ...
Page 242: ...242 Upgrade and Maintenance Manual GX2460 M1 Appendix A ...
Page 244: ...244 Upgrade and Maintenance Manual GX2460 M1 Appendix B ...
Page 250: ...RAID Card RAID Card HDD Back Plane 411T61300070 SAS MLC1 SAS MLC2 SATA 0 3 SATA 4 7 C17 C17 ...