CX122 S1
Operating Manual
11
Technical data
1.5
Technical data
Electrical data
Rated voltage range
200 V - 240 V
Rated frequency
50 Hz - 60 Hz
Max. rated current
200 V - 240 V / 2.0 A
Rated current X5500 series CPUs 200 V - 240 V / 1.8 A
Rated current E5500 series CPUs 200 V - 240 V / 1.0 A
Rated current L5500 series CPUs 200 V - 240 V / 0.8 A
Rated current idle mode
200 V - 240 V / 0.3 A
(depending on configuration / application)
Effective power
(X / E / L series CPUs)
286 W / 192 W / 185 W
(depending on configuration / application)
Apparent power
(X / E / L series CPUs)
302 VA / 206 VA / 200 VA
(depending on configuration / application)
Heat dissipation
(X / E / L series CPUs)
1029 KJ/h (975 btu/h)
691 KJ/h (654 btu/h)
666 KJ/h (631 btu/h)
Main power fuse EMEA
16 A
Main power fuse NORAM
20 A
Protection class
I
Summary of Contents for PRIMERGY CX122 S1
Page 1: ...Operating Manual English PRIMERGY CX122 S1 Server Operating Manual Edition November 2010 ...
Page 14: ...14 Operating Manual CX122 S1 Technical data ...
Page 16: ...16 Operating Manual CX122 S1 ...
Page 38: ...38 Operating Manual CX122 S1 Connecting devices and cables ...
Page 48: ...48 Operating Manual CX122 S1 Configuring the server ...