A26361-K632-Z100-1-7619
77
Technical data
Electrical data
Rated voltage range:
100 V - 125 V / 200 V - 240 V
Frequency:
50 Hz - 60 Hz
Rated current in basic configuration:
•
Server without monitor outlet or monitor
outlet is not used
100 V - 125 V /
1,8 A
200 V - 240 V
1,0 A
Max. rated current:
•
Server without monitor outlet or monitor
outlet is not used
•
Server with monitor socket
•
Monitor socket
100 V - 125 V /
6,0 A
200 V - 240 V
3,5 A
100 V - 125 V /
9,0 A
200 V - 240 V
5,0 A
100 V - 125 V /
3.0 A
200 V - 240 V
1,5 A
Protection class:
I
Regulations complied with:
EN 60950 / VDE 0805
UL 1950
CSA 22.2 No 950
Dimensions of tower server (including door and feet)
Width:
Depth:
Height:
Weight:
288 mm
685 mm
480 mm
approx. 18 - 35 kg
Dimensions of rack server (including rails and installed in rack)
Width:
Depth:
Height:
Weight:
483 mm
754 mm
266 mm
approx. 18 - 35 kg
Environmental conditions
Environment class 3K2
Environment class 2K2
DIN IEC 721 part 3-3
DIN IEC 721 part 3-2
Temperature:
•
Operating (3K2)
•
Transport (2K2)
15 °C .... 35 °C
-25 °C .... 60 °C
Condensation in operating must be avoided.
Noise level
Sound power level L
WAd
(ISO 9296):
≤
5.8 dB
Sound pressure level
at bystander position L
pAm
(ISO 9296):
≤
43 dB