C141-E093-01EN
4 - 9
4.5.2
Execution timing of self-calibration
Self-calibration is executed when:
•
The power is turned on.
•
The self-calibration execution timechart of the disk drive specifies self-calibration.
The disk drive performs self-calibration according to the timechart based on the time elapsed
from power-on. The timechart is shown in Table 4.1. After power-on, self-calibration is
performed about every 30 minutes.
Table 4.1
Self-calibration execution timechart
Time elapsed
Time elapsed (accumulated)
1
At power-on
Initial calibration
2
About 30 minutes
About 30 minutes
3
About 30 minutes
About 60 minutes
4
About 30 minutes
About 90 minutes
5
About 30 minutes
About 120 minutes
6
About 30 minutes
About 150 minutes
7
.
.
.
9
Every about 30 minutes
4.5.3
Command processing during self-calibration
If the disk drive receives a command execution request from the host while executing self-
calibration according to the timechart, the disk drive terminates self-calibration and starts
executing the command precedingly. In other words, if a disk read or write service is
necessary, the disk drive positions the head to the track requested by the host, reads or writes
data, and restarts calibration.
This enables the host to execute the command without waiting for a long time, even when the
disk drive is performing self-calibration. The command execution wait time is about
maximum 100 ms.
Summary of Contents for MPE3043AE
Page 1: ...C141 E093 02EN MPE3xxxAE DISK DRIVES PRODUCT MANUAL ...
Page 3: ...This page is intentionally left blank ...
Page 7: ...This page is intentionally left blank ...
Page 15: ...This page is intentionally left blank ...
Page 31: ...C141 E093 02EN 3 2 Figure 3 1 Dimensions ...
Page 45: ...This page is intentionally left blank ...
Page 50: ...C141 E093 01EN 4 5 Figure 4 2 MPE3xxxAE Block diagram ...
Page 183: ......