C141-E055-01EN
5 - 47
At command issuance (I/O registers setting contents)
1F7
H
(CM)
X'98' or X'E5'
1F6
H
(DH)
×
×
×
DV
xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(FR)
xx
xx
xx
xx
xx
At command completion (I/O registers contents to be read)
1F7
H
(ST)
Status information
1F6
H
(DH)
×
×
×
DV
xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(ER)
xx
xx
xx
X'00' or X'FF'
Error information
(28)
SMART (X'B0)
This command performs operations for device failure predictions according to a subcommand
specified in the FR register. If the value specified in the FR register is supported, the Aborted
Command error is posted.
It is necessary for the host to set the keys (CL = 4Fh and CH = C2h) in the CL and CH
registers prior to issuing this command. If the keys are set incorrectly, the Aborted Command
error is posted.
In the default setting, the failure prediction feature is disabled. In this case, the Aborted
Command error is posted in response to subcommands other than SMART Enable Operations
(FR register = D8h).
When the failure prediction feature is enabled, the device collects or updates several items to
forecast failures. In the following sections, note that the values of items collected or updated
by the device to forecast failures are referred to as attribute values.
Summary of Contents for MPC3032AT
Page 3: ...This page is intentionally left blank ...
Page 7: ...This page is intentionally left blank ...
Page 15: ...This page is intentionally left blank ...
Page 31: ...This page is intentionally left blank ...
Page 33: ...C141 E055 02EN 3 2 Figure 3 1 Dimensions ...
Page 48: ...C141 E055 01EN 4 5 Figure 4 2 MPC30xxAT Block diagram ...
Page 54: ...C141 E055 01EN 4 11 Figure 4 4 Read write circuit block diagram ...
Page 179: ......