4.4 Various Processes
C156-E227-01EN
4-13
4.4 Various Processes
4.4.1 Reset response
There are four types of resets.
•
Power-on reset
−
The ODD performs initialization such as initial diagnostics and default
setting. If any media is mounted, it also spins up media.
•
Hardware reset
−
The ODD is reset when the RESET- signal is asserted. The ODD
initializes the interface controller by setting default values.
•
ATA software reset
−
The ODD is reset when the SRST bit of the Device Control register is set.
−
The device driver should not use the SRST bit to reset the ODD (except
for restore from sleep mode).
−
After ATA software reset, the ODD initializes the task file as shown
below.
Status = 00h
Error = (Depending on the SRST sequence)
Sector Count = 01h
Sector number = 01h
Cylinder Low = 14h
Cylinder High = EBh
Drive/Head = 00h
−
DRDY is set to 1 with the first command after ATA reset.
−
If ATA software reset is issued while the ODD is selected and a
command is being executed (BSY = 1 or DRQ = 1), the command is
interrupted. Otherwise, the ODD continues command processing.
−
The contents set with the MODE SELECT and Set Features commands
remain unchanged.
•
ATAPI reset
−
The ODD is reset with a DEVICE RESET command. The ODD
interrupts the current command.
Summary of Contents for MCM3064AP
Page 1: ...C156 E227 01EN MCM3064AP MCM3130AP OPTICAL DISK DRIVES PRODUCT MANUAL ...
Page 4: ...This page is intentionally left blank ...
Page 8: ...This page is intentionally left blank ...
Page 32: ...This page is intentionally left blank ...
Page 50: ...Installation Requirements 3 6 C156 E227 01EN Figure 3 3 Outer dimensions 1 3 ...
Page 52: ...Installation Requirements 3 8 C156 E227 01EN Figure 3 3 Outer dimensions 3 3 ...
Page 190: ...This page is intentionally left blank ...
Page 198: ...This page is intentionally left blank ...
Page 200: ...This page is intentionally left blank ...
Page 201: ......
Page 202: ......